| Electronic Components Datasheet Search |
|
F39-LSGA Datasheet(PDF) 95 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
F39-LSGA Datasheet(HTML) 95 Page - Omron Electronics LLC |
|
95 / 109 page ![]() Common to F3SG-SR and F3SG-PG 95 Receiver (F3SG-SR/PG) *1. Refer to Troubleshooting on page 97 for more information on blinking patterns. *2. Configurable by SD Manager 3. *3. This is the case for the Standard Muting mode. For other muting modes, refer to User's Manual (Man.No.Z405). *4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR/PG blinks. *5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR/PG blinks. *6. DIP switches is on the Intelligent Tap. Note: In the SETTING state to make settings with the SD Manager 3, the TEST, LONG and CODE indicators on the emitter and the CFG, PNP and CODE indicators on the receiver blink. (TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green) For more information on the statuses of the LED indicators in the SETTING state, refer to User's Manual (Man.No.Z405). Location Indicator Name Color Illuminated Blinking F3SG-SRA F3SG-SRB F3SG-PG 1 Scan code Green Code A is selected --- X X X Orange Code B is selected OFF Automatic interference prevention by wired synchronization being performed 2 Lockout Red LOCKOUT state. The indicator is illuminated in the receiver of another sensor segment than that having a lockout error (when in cascade connection or between the emitter and receiver in the Wired Synchronization) LOCKOUT state. The indicator is illuminated in the receiver of a sensor segment having a lockout error X X X 3 ON/OFF Green Safety outputs are in ON state --- X X X Red Safety outputs are in OFF state LOCKOUT state due to Safety output error, or error due to abnormal power supply or noise X X X 4 Maintenance Red LOCKOUT state due to a recoverable error (Whenin cascade connection, the indicator of only the sensor segment having the error is illuminated) LOCKOUT state due to a replacement- recommended error (When in cascade connection, the indicator of only the sensor segment having the error blinks) X X X Orange Safety outputs are instantaneously turned OFF due to ambient light, vibration or noise. Or sequence error in Muting, Pre-Reset or PSDI Intelligent Tap is in the LOCKOUT state X X X 5 PNP/NPN mode Green PNP is configured Polarity of PNP is changed to NPN, or vice versa, during operation, and internal circuit is defective X X X OFF NPN is configured --- 6 Configuration Green Fixed or Floating Blanking, Reduced Resolution, Warning Zone or Slow mode of Response Time Adjustment is enabled. Or after the Muting zone is determined by the Dynamic Muting function. TEACH-IN mode, zone measurement being performed by Dynamic Muting, or LOCKOUT state due to Blanking monitoring error, Configuration error or Parameter error X X X 7 Sequence Yellow INTERLOCK state Sequence or sequence error in Muting, Pre- Reset or PSDI (*1) or Teach-in error X X X 8 --- Area Beam Indicator (ABI) Green The target beams of the ABI are unblocked and the safety outputs are turned ON MUTING or OVERRIDE state. In the MUTING state, only the ABI indicators in the muting zone are blinking. Or the target beams of the ABI are blocked instantaneously X --- X Orange Incident light level of the target beams of the ABI is 170% (factory default setting (*2)) or less of ON- threshold (for 5 to 10 s) Incident light level of the target beams of the ABI is 170% (factory default setting (*2)) or less of ON threshold 5 to 10 s after illuminated when incident light level of the target beams of the ABI is 170% (factory default setting (*2)) or less of ON threshold. Or one muting input becomes the ON state and the MUTING state has not been started yet, or one muting input becomes the OFF state and the other is not in the OFF state yet. (*3) Red The target beams of the ABI are blocked LOCKOUT state due to Cap error or Other sensor error (*4), or LOCKOUT state due to DIP Switch setting error (*5*6) OFF The target beams of the ABI are unblocked (The ABI then will be illuminated in green when the safety outputs are turned ON.) --- 9 TOP Top-beam- state Blue The top beam is unblocked MUTING/OVERRIDE state, or LOCKOUT state due to Cap error or Other sensor error --- X --- 10 BTM Bottom- beam-state Blue The bottom beam is unblocked MUTING/OVERRIDE state, or LOCKOUT state due to DIP Switch setting error (*6) --- X --- CODE C or ERR E or OSSD O or MAINT M or PNP P or CFG F or SEQ S or |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |