| Electronic Components Datasheet Search |
|
L6713ATR Datasheet(PDF) 57 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6713ATR Datasheet(HTML) 57 Page - STMicroelectronics |
|
57 / 64 page ![]() L6713A Tolerance band (TOB) definition 57/64 23.4 Temperature measurement error (VTC) Error in the measured temperature (for thermal compensation) impacts on the output regulated voltage since the correction form the compensation circuit is not what required to keep the output voltage flat. The measurement error ( ε Temp) must be multiplied by the copper temp coefficient (α) and compared with the sensing resistance (RSENSE): this percentage affects the AVP voltage as follow: V TC αε Temp ⋅ R SENSE ------------------------ V AVP ⋅ = |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|