33 / 52 page ![]() 33 57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™ 6.0 Diagnostic Parameters The Eclipse Model 705 measurement engine runs through a series of self-tests and will detect and report faulty opera- tion. The TRANSDUCER BLOCK displays these faults in the DEVICE_STATUS parameter. Refer to Section 7.1.2 for more information on specific faults and warnings. When the Model 705 transmitter is initially powered on, the measurement engine does not have enough valid meas- urement cycles to make a decision about the output level. For the first sixteen measurement cycles after power is applied, the QUALITY is “Uncertain,” the SUB_STATUS is “Initial value,” and the LIMIT attribute is “Constant.” 54 ElecTemp xxx C None Diagnostic Display Present temperature in electronics compartment (degrees Celsius) 55 Max Temp xxx C Superuser Diagnostic Display Maximum electronics temperature recorded 56 Min Temp xxx C Superuser Diagnostic Display Minimum electronics temperature recorded 57 SZ Hyst xx.x su Superuser Superuser Parameter Safety Zone hysteresis height Display Password Action Comment 41 Compsate Superuser Superuser Parameter Select from None, Manual, Auto 42 DrateFct xxxx None Diagnostic Display Compsate = Auto, velocity derating factor 43 TargAmpl xxxx None Diagnostic Display Compsate = Auto, target negative threshold amplitude 44 Targ Tks xxxx None Diagnostic Display Compsate = Auto, measured time of flight from fiducial to target 45 Targ Cal xxxx Superuser Diagnostic Display Compsate = Auto, calibrated time of flight from fiducial to target in room temperature air 46 OperMode (select) Superuser Superuser Parameter Compsate = Auto, select from Run, Cal, Off 47 7xK Corr xxx Superuser Superuser Parameter Probe Model = 7xK, Distance in mm from fiducial to user reference point 48 Snsr Val xxx.x su None Distance to the target relative to the sensor reference point. 49 SnrCalLo xxx.x su Superuser The lower calibrated point of Sensor Value. It refers to PrLvl Lo. In Sensor Units. Set to entered Probe Ln 50 SnrCalHi xxx.x su Superuser The higher calibrated point of Sensor Value. It refers to PrLvl Hi. In Sensor Units 51 ProbeLvl xxx.x plu None Level on the probe relative to the end of the probe. 52 PrLvl Lo xxx.x plu Superuser Value of PrLvl at SnrCalLo. In Probe Level Units 53 PrLvl Hi xxx.x plu Superuser Value of PrLvl at SnrCalHi. In Probe Level Units |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |