| Electronic Components Datasheet Search |
|
705-5100-F21 Datasheet(PDF) 38 Page - Magnetrol International, Inc. |
|
|
|||||||||||||||||||||||||||||
705-5100-F21 Datasheet(HTML) 38 Page - Magnetrol International, Inc. |
|
38 / 52 page ![]() 38 57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™ 7.1.3 Error Mapped to Diagnosis (cont.) Note that PV status for Interface and Volume process vari- bles may indicate a configuration error if the correct Measurement Type has not been selected. In this case, “Configuration not valid” will not be set in the DIAGNO- SIS parameter since level measurement may still be correct. Also, a Default Parameters Fault is indicated after a Factory Reset which will result in the DIAGNOSIS indication “Configuration not valid”. 7.1.4 PROFIBUS PA TM Segment Checklist There can be several reasons for a PROFIBUS PA™ installa- tion to be in a faulty condition. In order to assure that com- munication can be established, the following requirements must be met. • Device supply voltage must be higher than 9 VDC with a maximum of 32 VDC. • Total current draw of a given segment cannot exceed the rating shown on the power conditioner and/or barrier. • Device polarity must be correct. • Two 100 Ω, 1 µF terminators must be connected to the network—one at each end of the segment. • Cable length plus spur length must not exceed the following values: • The cable shield is to be hard grounded only at one point close to the DCS. In addition, the cable shield can be capacitively grounded in multiple places to improve EMC protection. If all of these requirements are met, a stable communication should be established. Number of Spurs 1 Device 2 Devices 3 Devices 4 Devices 25–32 — — — — 19–24 100 ft. (30 m) — — — 15–18 200 ft. (60 m) 100 ft. (30 m) — — 13–14 300 ft. (90 m) 200 ft. (60 m) 100 ft. (30 m) — 1–12 400 ft. (120 m) 300 ft. (90 m) 200 ft. (60 m) 100 ft. (30 m) Pair Shield Twisted Size Length Type Single Yes Yes AWG 18 (0.8 mm2) 6,200 ft. (1,900 m) A Multi Yes Yes AWG 22 (0.32 mm2) 3,900 ft. (1,200 m) B Multi No Yes AWG 26 (0.13 mm2) 1,300 ft. (400 m) C Multi Yes No AWG 16 (1.25 mm2) 650 ft. (200 m) D |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |