35 / 52 page ![]() 35 57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™ LEVEL and % OUTPUT values Basic configuration data is Reconfigure the Probe Model and/or Probe are inaccurate. questionable. Mount, Probe Length or Level Offset. 1) Ensure the Level is accurate. Interface level has significant emulsion. Examine process to reduce/eliminate emulsion layer. LEVEL readings are repeatable but Configuration data does not Ensure proper Probe Model, Level Offset consistently high or low from actual accurately match probe length & probe length. by a fixed amount. or tank height. Adjust trim level value by the amount of noted inaccuracy. LEVEL and % OUTPUT values Turbulence Increase the Damping factor until the fluctuate. readings stabilize. High Frequency connection Check Fid Spread (should be stable within ±10 counts). LEVEL and % OUTPUT values Lower dielectric material over higher Select Fixed Threshold option. all reading low vs. actual. dielectric material, e.g., oil over water Coating, clumping or buildup on probe These may be expected inaccuracies due to affect on pulse propagation. Dense, water based foam These may be expected inaccuracies due to affect on pulse propagation. Level Reading on Display is stuck at Software believes probe is flooded Check actual level. If probe is not flooded, full scale. (level near very top of probe). Check for buildup or obstructions near top of probe. Select higher dielectric range. Check for condensation in probe connection. Add Blocking Distance. LEVEL and % OUTPUT values Possible configuration issue 1) Increase Blocking Distance values all at maximum level. with single rod probe 2) Increase Dielectric Range LEVEL and % OUTPUT values Possible obstruction in tank 1) Increase Dielectric Range until reading high vs. actual. affecting single rod probe obstruction is ignored 2) Relocate probe away from obstruction LEVEL value reading high when Transmitter loose or disconnected Ensure transmitter connected securely should be zero. from probe to probe. Symptom Problem Solution 7.1.1 Troubleshooting System Problems NOTE: When consulting the factory concerning improper operation, use proper tables on Pages 50-51. Enter all data when transmitter is working CORRECTLY and INCORRECTLY. 7.0 Reference Information 7.1 Troubleshooting The Eclipse transmitter is designed and engineered for trouble-free operation over a wide range of operating conditions. Common transmitter problems are discussed in terms of their symptoms and recommended corrective actions. Information on how to handle material buildup on the probe is also provided in this section. WARNING! Explosion hazard. Do not connect or disconnect equipment unless power has been switched off or the area is known to be non-hazardous. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |