| Electronic Components Datasheet Search |
|
KMA310 Datasheet(PDF) 17 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
KMA310 Datasheet(HTML) 17 Page - NXP Semiconductors |
|
17 / 71 page ![]() NXP Semiconductors KMA310 Programmable angle sensor IC KMA310 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2019. All rights reserved. Product data sheet Rev. 3 — 27 February 2019 17 / 71 Table 29. OEM_CODE_7[11:0] – OEM code 7 message 8-bit ID 12-bit code Definition Comment 96h 000h to FFFh OEM code 7 user-programmable data content Table 30. OEM_CODE_8[11:0] – OEM code 8 message 8-bit ID 12-bit code Definition Comment 97h 000h to FFFh OEM code 8 user-programmable data content 8.11 SENT diagnostic The SENT standard specifies different methods to transmit diagnostic information. These methods are used in multiple combinations, depending on the SENT revision, protocol format, and device configuration. 8.11.1 STATUS nibble diagnostic Bit 0 and bit 1 of the STATUS nibble can be used to signal the diagnostic state while the DATA nibbles still contain an angular value at the same time. The CRC nibble does not include the STATUS nibble, thus the receiver do not detect an erroneous STATUS nibble. 8.11.1.1 Diagnostic bit The device defines bit 0 of the STATUS nibble as diagnostic bit. In case the device is in diagnostic mode the diagnostic bit is set to logic 1. The diagnostic bit can be disabled and permanently set to logic 0 via the mask STATUS nibble bits in the SENT_SETTING2 register in the non-volatile memory; see Table 51. 8.11.1.2 Pre-warning bit Bit 1 is a pre-warning indication which is set while the device is still in normal mode, but one of the following conditions occurred: • The angular value is above the programmed upper out of range (OOR) threshold; see Table 53. • The angular value is below the programmed lower OOR threshold; see Table 53. • Corrected single-bit error of the non-volatile memory (EDC); see Section 10.1. • The temperature is above the programmed temperature threshold; see Table 51. • Overvoltage: The supply voltage is above the programmed upper voltage threshold; see Table 51. • Undervoltage: The supply voltage is below the programmed lower voltage threshold; see Table 51. The pre-warning bit can be disabled and permanently set to logic 0 via the mask STATUS nibble bits in the SENT_SETTING2 register in the non-volatile memory; see Table 51. 8.11.2 Fast channel diagnostic value Some protocol formats define a reserved data range in the fast channel communication for signaling diagnostic status instead of an angular value in the SENT transmission. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |