| Electronic Components Datasheet Search |
|
TLD2132-1EP Datasheet(PDF) 30 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
TLD2132-1EP Datasheet(HTML) 30 Page - Infineon Technologies AG |
|
30 / 41 page ![]() Datasheet 30 Rev. 1.10 2019-09-26 TLD2132-1EP LITIX™ Basic+ Load diagnosis The fault status is not latched: as soon as the fault condition is no longer present (at least for a filter time tfault), ERRN goes back to high impedance and, once its voltage is above VERRN(fault), finally the output stages are activated again. Examples of open load or short to GND diagnosis with D-pin open or connected to GND are shown in the timing diagrams of Figure 20 and Figure 21. Figure 20 Open load condition timing diagram example (D-pin connected to GND, VF represents the forward voltage of the output load) t tfault VOUT VF VS VER RN (fault) VERRN open load occurs open load disappears VS – VPS (O L) t VIN_SE T(ref) VIN_SET t tfault |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|