Back Button TLD2132-1EP Datasheet HTML 30Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 31Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 32Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 33Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 34Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 35Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 36Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 37Page - Infineon Technologies AG TLD2132-1EP Datasheet HTML 38Page - Infineon Technologies AG Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 41 page
background image
Datasheet
34
Rev. 1.10
2019-09-26
TLD2132-1EP
LITIX™ Basic+
Load diagnosis
Then (differently from the management of OL and SC detection) the voltage at DS pin also starts rising with a
pull-up current IDS(PU), until it reaches the threshold VDS(H), when it starts discharging with the current IDS(PD).
Now the DS voltage can cross the lower voltage threshold VDS(L): at this time a full wait time cycle tSL_WAIT is
completed and the device performs a load reactivation retry, turning the output current back on. If the SLS
fault condition persists, a new tSL_WAIT cycle is started. If at the end of one wait cycle the fault is not detected
anymore, the device goes back to normal operation. The dimensioning of typical tSL_WAIT is ruled by the
following equations.
(6.5)
(6.6)
(6.7)
A graphical description is shown in the timing diagram example of Figure 24.
With this error management algorithm, it is possible to detect the SLS fault monitoring the device
consumption from the VS line, which remains as low as IS(fault) during the whole wait cycle.
Figure 24
Single LED short condition timing diagram example (D pin not connected or connected to
external capacitor to GND) output load)
6.3.5
SLS fault management: D-pin shorted to GND
Under D-pin shorted to GND configuration, the output affected by a single LED short fault is not turned off,
different from an open load or short circuit to GND fault condition. The potential on the IN_SET pin remains
)
(
)
(
)
(
PU
DS
H
DS
DS
rise
DS
I
V
C
t
⋅
=
(
)
)
(
)
(
)
(
)
(
)
(
)
(
PD
DS
H
DS
DS
PD
DS
L
DS
H
DS
DS
fall
DS
I
V
C
I
V
V
C
t
⋅
≈
−
⋅
=
)
(
)
(
_
)
(
)
(
)
(
rise
DS
del
SET
IN
fall
DS
rise
DS
wait
SL
t
t
t
t
t
≈
+
+
=
VOUT
t
VERRN
VERRN(fault)
t
tfault
tD(set)
tD(reset)
VD
VD(th)
VDS
VIN_SET
t
tIN_SET(del)
VIN_SET(ref)
tfault
VDS(H)
VDS(L)
t
tSL(wait)
t
SLS fault
appears
SLS fault
disappears
Retry +
Restart
B*VSLS_REF
VOUT(typ)
VOUT(SLS)
Active
Retry
tfault
tIN_SET(del)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com