| Electronic Components Datasheet Search |
|
71M6541D/F/G Datasheet(PDF) 127 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
71M6541D/F/G Datasheet(HTML) 127 Page - Maxim Integrated Products |
|
127 / 166 page ![]() 71M6541D/F/G and 71M6542F/G Data Sheet Rev 5 127 The parameters EQU[2:0] (I/O RAM 0x2106[7:5]), CE_E (I/O RAM 0x2106[0]), and SUM_SAMPS[12:0] are essential to the function of the CE are stored in I/O RAM (see 5.2 I/O RAM Map – Alphabetical Order for details). 5.3.4 Environment Before starting the CE using the CE_E bit (I/O RAM 0x2106[0]), the MPU has to establish the proper environment for the CE by implementing the following steps: • Locate the CE code in Flash memory using CE_LCTN[5:0] (I/O RAM 0x2109[5:0]) • Load the CE data into RAM • Establish the equation to be applied in EQU[2:0] (I/O RAM 0x2106[7:5]) • Establish the number of samples per accumulation period in SUM_SAMPS[12:0] (I/O RAM 0x2107[4:0], 0x2108[7:0]) • Establish the number of cycles per ADC multiplexer frame (MUX_DIV[3:0] (I/O RAM 0x2100[7:4])) • Apply proper values to MUXn_SEL, as well as proper selections for DIFFn_E (I/O RAM 0x210C[5:4]) and RMT_E (I/O RAM 0x2709[3]) in order to configure the analog inputs • Initialize any MPU interrupts, such as CE_BUSY, XFER_BUSY, or the power failure detection interrupt • VMAX = 600 V, IMAX = 707 A, and kH = 1 Wh/pulse are assumed as default settings When different CE codes are used, a different set of environment parameters need to be established. The exact values for these parameters are listed in the Application Notes and other documentation which accompanies the CE code. Operating CE codes with environment parameters deviating from the values specified by Maxim leads to unpredictable results. See Table 1 and Table 2. Typically, there are thirteen 32768 Hz cycles per ADC multiplexer frame (see 2.2.2 Input Multiplexer). This means that the product of the number of cycles per slot and the number of conversions per frame must be 12 (plus one settling cycle per frame, see Figure 6 and Figure 7). The default configuration is FIR_LEN[1:0] = 01, I/O RAM 0x210C[2:1], (three cycles per conversion) and MUX_DIV[3:0] = 3 (3 conversions per multiplexer cycle). Sample configurations can be copied from Demo Code provided by Maxim with the Demo Kits. 5.3.5 CE Calculations Referring to Table 78, The MPU selects the desired equation by writing the EQU[2:0] (I/O RAM 0x2106[7:5]). Table 78: CE EQU Equations and Element Input Mapping EQU Watt & VAR Formula (WSUM/VARSUM) Inputs Used for Energy/Current Calculation W0SUM/ VAR0SUM W1SUM/ VAR1SUM I0SQ SUM I1SQ SUM 0 VA IA – 1 element, 2W 1 f VA*IA VA*IB IA – 1 VA*(IA-IB)/2 – 1 element, 3W 1 f VA*(IA-IB)/2 – IA-IB IB 2 † VA*IA + VB*IB – 2 element, 3W 3 f Delta VA*IA VB*IB IA IB Note: † 71M6542F/G only. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |