Back Button DRV5032 Datasheet HTML 12Page - Texas Instruments DRV5032 Datasheet HTML 13Page - Texas Instruments DRV5032 Datasheet HTML 14Page - Texas Instruments DRV5032 Datasheet HTML 15Page - Texas Instruments DRV5032 Datasheet HTML 16Page - Texas Instruments DRV5032 Datasheet HTML 17Page - Texas Instruments DRV5032 Datasheet HTML 18Page - Texas Instruments DRV5032 Datasheet HTML 19Page - Texas Instruments DRV5032 Datasheet HTML 20Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 16 / 39 page
background image
8 Application and Implementation
Note
Information in the following applications sections is not part of the TI component specification,
and TI does not warrant its accuracy or completeness. TI’s customers are responsible for
determining suitability of components for their purposes, as well as validating and testing their design
implementation to confirm system functionality.
8.1 Application Information
The DRV5032 device is typically used to detect the proximity of a magnet. The magnet is often attached to a
movable component in the system.
8.1.1 Output Type Tradeoffs
The push-pull output allows for the lowest system power consumption because there is no current leakage path
when the output drives high or low. The open-drain output involves a leakage path through the external pullup
resistor when the output drives low.
The open-drain outputs of multiple devices can be tied together to form a logical AND. In this setup, if any sensor
drives low, the voltage on the shared node becomes low. This can allow a single GPIO to measure an array of
sensors.
8.2 Typical Applications
8.2.1 General-Purpose Magnet Sensing
OUT
DRV5032
GPIO
VCC
Controller
VCC
GND
distance
N S
Copyright © 201 7, Texas Instrumen ts Incorpor ate d
Figure 8-1. Typical Application Diagram
8.2.1.1 Design Requirements
For this design example, use the parameters listed in Table 8-1.
Table 8-1. Design Parameters
DESIGN PARAMETER
EXAMPLE VALUE
VCC
3.3 V
Magnet
1-cm Cube NdFeB
Closest magnet distance
2.5 cm
Magnetic flux density at closest distance
7.8 mT
Magnetic flux density when magnet moves away
Close to 0 mT
8.2.1.2 Detailed Design Procedure
When designing a digital-switch magnetic sensing system, consider these three variables: the magnet, sensing
distance, and threshold of the sensor.
DRV5032
SLVSDC7G – APRIL 2017 – REVISED JULY 2024
www.ti.com
16
Submit Document Feedback
Copyright © 2024 Texas Instruments Incorporated
Product Folder Links: DRV5032



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com