29 / 32 page ![]() PAXI: CALIBRATION 29 TROUBLESHOOTING For further assistance, contact technical support at the appropriate company numbers listed. PROBLEM REMEDIES NO DISPLAY CHECK: Power level, power connections PROGRAM LOCKED-OUT CHECK: Active (lock-out) user input ENTER: Security code requested CERTAIN DISPLAYS ARE LOCKED OUT CHECK: Module 3 programming INCORRECT DISPLAY VALUE or NOT COUNTING CHECK: Input wiring, DIP switch setting, input programming, scale factor calculation, input signal level, user input jumper, lower input signal frequency USER INPUT NOT WORKING CORRECTLY CHECK: User input wiring, user input jumper, user input being used for signal, Module 2 OUTPUT DOES NOT WORK CHECK: Corresponding option card installation, output configuration, output wiring JITTERY DISPLAY CHECK: Wiring is per EMC installation guidelines, input signal frequency, signal quality, scaling, update time, DIP switch setting “ ” RATE CHECK: Lower input signal frequency, reduce rate scaling MODULES or PARAMETERS NOT ACCESSIBLE CHECK: Corresponding option card installation, related controlling parameter selected ERROR CODE ( ) PRESS: Reset key (if unable to clear contact factory.) SERIAL COMMUNICATIONS CHECK: Wiring, connections, meter and host settings Analog Output Card Calibration Before starting, verify that a precision meter with an accuracy of 0.05% or better (voltmeter for voltage output and/or current meter for current output) is connected and ready. Then perform the following procedure: 1. Use the arrow keys to display and press PAR. 2. is displayed. Use the arrow keys to select and press PAR. 3. Using the chart below, step through the five selections to be calibrated. At each prompt, use the PAXI arrow keys to adjust the output so that the external meter display matches the selection being calibrated. When the external reading matches, or if the range is not being calibrated, press PAR. SELECTION EXTERNAL METER ACTION 00 0.00 Adjust if necessary, press PAR 0 4.00 Adjust if necessary, press PAR 00 20.00 Adjust if necessary, press PAR 00 0.00 Adjust if necessary, press PAR 00 10.00 Adjust if necessary, press PAR 4. When appears, press PAR twice and remove the external meters. The only item in the PAXI meter that can be calibrated is the Analog Output. The Count A and B values are scaled using the parameters in Module 1, Counter C value is scaled using Module 5 and the Rate value is scaled using Module 4. If the meter appears to be indicating incorrectly or inaccurately, refer to the Troubleshooting section. When Analog Out recalibration is required (generally every 2 years), it should be performed by qualified technicians using appropriate equipment. Calibration does not change any user programmed parameters. Calibration may be aborted by disconnecting power to the meter before exiting Module 9. In this case, the existing calibration settings remain in effect. Note: Allow a 30 minute warm-up period before staring calibration. Shaded areas are model dependent. INPUT A AND B LOGIC SELECTION The Count Inputs A and B are factory configured for falling edge triggered (active low) operation in single edge count modes. The Counter Operating Mode descriptions in the Input programming section reflect this logic. If an application is better suited to use rising edge triggered (active high) operation, the Input Logic for Input A and/or Input B can be changed by entering Code 55. Selecting sets the Input A logic to rising edge triggered (active high) operation. Be advised that all references to Input A falling edge and Input A rising edge will be reversed for the Counter Operating Mode descriptions. Selecting sets the Input B logic to rising edge triggered (active high) operation. Be advised that all references to Input B falling edge and Input B rising edge will be reversed for the Counter Operating Mode descriptions. The meter briefly displays the unit type followed by the current firmware version ( x.x), and then returns to . This information is also displayed during the meter power-up sequence. UNIT TYPE AND VERSION |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |