| Electronic Components Datasheet Search |
|
PAXUSB00 Datasheet(PDF) 28 Page - Red Lion Controls. Inc |
|
|
|||||||||||||||||||||||||||||
PAXUSB00 Datasheet(HTML) 28 Page - Red Lion Controls. Inc |
|
28 / 32 page ![]() PAR Pro 8-AnA ASIN Analog Type tYPE AN-LO AN-HI Analog Assignment Analog Low Scale Value Analog High Scale Value 28 ANALOG ASSIGNMENT ANALOG LOW SCALE VALUE ANALOG HIGH SCALE VALUE PARAMETER MENU d-LEV Display Intensity Level PAR 9-FCS Pro Factory Service Code COdE PARAMETER MENU ANALOG TYPE Enter the analog output type. For voltage output use terminals 16 and 17. For current output use terminals 18 and 19. Only one range can be used at a time. Select the display that the analog output is to follow: Enter the display value within the selected Analog Assignment that corresponds to the high limit of the type selected. The decimal point is determined by the decimal point setting of the assigned counter or rate. The scale value can not be set to read values with more than 6 digits. Reverse acting output is possible by reversing the scaling values. 99999 to 999999 99999 to 999999 Module 8 is the programming for the analog output parameters. To have an analog output signal, an analog output option card needs to be installed (See Ordering Information). For analog output hardware and wiring details, refer to the bulletin shipped with the option card. SELECTION RANGE 00 0 to 20 mA 0 4 to 20 mA 00 0 to 10 V Enter the display value within the selected Analog Assignment that corresponds to the low limit of the type selected. The decimal point is determined by the decimal point setting of the assigned counter or rate. The scale value can not be set to read values with more than 6 digits. Reverse acting output is possible by reversing the scaling values. RESTORE FACTORY DEFAULTS Use the arrow keys to display and press PAR. The meter will display and then returns to . Press DSP key to return to the Display Mode. This will overwrite all user settings with the factory settings. Pressing the PAR and DSP keys at the same time on power-up will load the factory settings and display . This allows operation in the event of a memory failure or corrupted data. Immediately press RST key and reprogram the meter. If the meter is powered down again before pressing the RST key, the existing dynamic data will not be overwritten. 6.8 mOdule 8 - analOg OuTpuT parameTers () 6.9 mOdule 9 - faCTOry serviCe OperaTiOns () Enter the desired Display Intensity Level (0-15) by using the arrow keys. The display will actively dim or brighten as the levels are changed. This parameter also appears in Quick Programming Mode when enabled. DISPLAY INTENSITY LEVEL paXi Only = Counter C Value = Maximum Value = Counter B Value = Minimum Value = Counter A Value = Rate Value |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |