25 / 32 page ![]() 25 REGISTER ADDRESS REGISTER NAME LOW LIMIT HIGH LIMIT FACTORY SETTING ACCESS COMMENTS 40027 Setpoint 2 Value (Hi word) -199999 999999 200 Read/Write Active List (A or B) 40028 Setpoint 2 Value (Lo word) 40029 Setpoint 3 Value (Hi word) -199999 999999 300 Read/Write Active List (A or B) 40030 Setpoint 3 Value (Lo word) 40031 Setpoint 4 Value (Hi word) -199999 999999 400 Read/Write Active List (A or B) 40032 Setpoint 4 Value (Lo word) Manual Mode Registers 40036 Manual Mode Register (MMR) 0 31 0 Read/Write Bit State: 0 = Auto Mode, 1 = Manual Mode Bit 4 = S1, Bit 3 = S2, Bit 2 = S3, Bit 1 = S4, Bit 0 = Linear Output 40037 Analog Output Register (AOR) 0 4095 0 Read/Write Linear Output Card written to only if Linear Output is in Manual Mode (MMR bit 0 = 1). 40038 Setpoint Output Register (SOR) 0 15 N/A Read/Write Status of Setpoint Outputs. Bit State: 0=Off, 1=On. Bit 3 = S1, Bit 2 = S2, Bit 1 = S3, Bit 0 = S4. Outputs can only be activated/reset with this register when the respective bits in the Manual Mode Register (MMR) are set. 40039 Reset Output Register 0 15 0 Read/Write Bit State: 1= Reset Output, bit is returned to zero following reset processing; Bit 3 = S1, Bit 2 = S2, Bit 1 = S3, Bit 0 = S4 SERIAL RLC PROTOCOL COMMUNICATIONS RLC Communications requires the Serial Communications Type Parameter (tYPE) be set to RLC Protocol (rLC). SENDING SERIAL COMMANDS AND DATA TO THE METER When sending commands to the meter, a string containing at least one command character must be constructed. A command string consists of a command character, a value identifier, numerical data (if writing data to the meter) followed by a command terminator character * or $. The <CR> is also available as a terminator when Counter C is in the SLAVE mode. Command Chart COMMAND DESCRIPTION NOTES N Node (Meter) Address Specifier Address a specific meter. Must be followed by a two digit node address. Not required when address = 00. T Transmit Value (read) Read a register from the meter. Must be followed by register ID character V Value Change (write) Write to register of the meter. Must be followed by register ID character and numeric data. R Reset Reset a register or output. Must be followed by register ID character. P Block Print Request Initiates a block print output. Registers are defined in programming. Command String Construction The command string must be constructed in a specific sequence. The meter does not respond with an error message to invalid commands. The following procedure details construction of a command string: 1. The first characters consist of the Node Address Specifier (N) followed by a 1 or 2 character address number. The address number of the meter is programmable. If the node address is 0, this command and the node address itself may be omitted. For node address 1 through 9, a leading zero character is not required. (The only exception is a numeric transmission when Counter C is set for slave mode.) This is the only command that may be used in conjunction with other commands. 2. After the optional address specifier, the next character is the command character. 3. The next character is the Register ID. This identifies the register that the command affects. The P command does not require a Register ID character. It prints according to the selections made in print options. 4. If constructing a value change command (writing data), the numeric data is sent next. 5. All command strings must be terminated with the string termination characters *, $ or when Counter C is set for slave mode <CR>. The meter does not begin processing the command string until this character is received. See Timing Diagram figure for differences between terminating characters. Sending Numeric Data Numeric data sent to the meter must be limited to the digit range shown under transmit details in the Register Identification Chart. Leading zeros are ignored. Negative numbers must have a minus sign. The meter ignores any decimal point and conforms the number to the scaled resolution. (For example: the meter’s scaled decimal point position = 0.0 and 25 is written to a register. The value of the register is now 2.5. Note: Since the meter does not issue a reply to value change commands, follow with a transmit value command for readback verification. Register Identification Chart ID VALUE DESCRIPTION MNEMONIC COMMAND TRANSMIT DETAILS A Count A CTA T, V, R 6 digit (V), 8 digit (T) B Count B CTB T, V, R 6 digit (V), 8 digit (T) C Count C CTC T, V, R 6 digit (V), 8 digit (T) D Rate RTE T, V 5 digit, positive only E Min (Lo) Value MIN T, V, R 6 digit, positive only F Max (Hi) Value MAX T, V, R 6 digit, positive only G Scale Factor A SFA T, V 6 digit, positive only H Scale Factor B SFB T, V 6 digit, positive only I Scale Factor C SFC T, V 6 digit, positive only J Counter Load A LDA T, V 5 negative / 6 positive K Counter Load B LDB T, V 5 negative / 6 positive L Counter Load C LDC T, V 5 negative / 6 positive M Setpoint 1 SP1 T, V, R 5 negative / 6 positive O Setpoint 2 SP2 T, V, R 5 negative / 6 positive Q Setpoint 3 SP3 T, V, R 5 negative / 6 positive S Setpoint 4 SP4 T, V, R 5 negative / 6 positive U Auto/Manual Register MMR T, V 0 – auto, 1 - manual W Analog Output Register AOR T, V 0 – 4095 normalized X Setpoint Register SOR T, V 0 – not active, 1 – active Command String Examples: 1. Address = 17, Write 350 to Setpoint 1. String: N17VM350$ 2. Address = 5, Read Count A value. String: N5TA* 3. Address = 0, Reset Setpoint 4 output. String: RS* |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |