20 / 32 page ![]() 20 20 6.6 mOdule 6 - seTpOinT (alarm) parameTers () Setpoint Annunciators Output Logic Setpoint Value Power-up State Setpoint Action Setpoint Assignment Boundary Type Setpoint Tracking SPSEL Setpoint Select PAR 6-SPt Lit-n SUP-n ACt-n ASN-n SP-n trC-n tYP-n Pro OUt-n tON-n On Time Delay HYS-n Setpoint Hysteresis Stb-n Standby Operation PAR tOFF-n Off Time Delay Reset w/SPn+1 Activates AUtO-n Counter Auto Reset tOUt-n Time-out Value Reset W/Display Reset rSd-n rSAS-n Reset w/SPn+1 Deactivates rSAE-n PARAMETER MENU Module 6 is the programming for the setpoint (alarms) output parameters. To have setpoint outputs, a setpoint option card needs to be installed into the PAX (see Ordering Information). Depending on the card installed, there will be two or four setpoint outputs available. For setpoint hardware and wiring details, refer to the bulletin shipped with the option card. For maximum input frequency, unused Setpoints should be configured for action. The setpoint assignment and the setpoint action determine certain setpoint feature availability. The chart below illustrates this. SETPOINT PARAMETER AVAILABILITY SETPOINT SELECT Select a setpoint (alarm output) to open the remaining module menu. (The “” in the following parameters will reflect the chosen setpoint number.) After the chosen setpoint is programmed, the display will default to . Select the next setpoint to be programmed and continue the sequence for each setpoint. Pressing PAR at will exit Module 6. SETPOINT ANNUNCIATORS disables the display of the setpoint annunciator. Normal () displays the corresponding setpoint annunciator of an “on” alarm output. Reverse () displays the corresponding setpoint annunciator of an “off” alarm output. flashes the display and the corresponding setpoint annunciator of an “on” alarm output. SETPOINT OUTPUT LOGIC Normal () turns the output “on” when activated and “off” when deactivated. Reverse () turns the output “off” when activated and “on” when deactivated. SETPOINT POWER UP STATE will restore the output to the same state it was at before the meter was powered down. will activate the output at power up. will deactivate the output at power up. Yes No Yes No No No Reset When SPn+1 Deactivates Yes No Yes No No No Reset When SPn+1 Activates Yes No Yes No No No Reset With Display Reset Yes No Yes No No No Counter Auto Reset No No Yes No No Yes Setpoint Time Out No No No Yes Yes Yes Setpoint On Delay No No No No Yes No Setpoint Off Delay No No No No Yes No Setpoint Hysteresis No Yes No Yes Yes Yes Standby Operation No Yes No Yes Yes Yes Boundary Type Yes Yes Yes Yes Yes Yes Setpoint Tracking Yes Yes Yes Yes Yes Yes Setpoint Value Yes Yes Yes Yes Yes Yes Power Up State Yes Yes Yes Yes Yes Yes Output Logic Yes Yes Yes Yes Yes Yes Annunciators LATCH BOUNDARY TIMED OUT LATCH BOUNDARY TIMED OUT COUNTER RATE DESCRIPTION PARAMETER |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |