14 / 32 page ![]() 14 PAXI: PRINT REQUEST PAXI: PRINT REQUEST AND RESET DISPLAYS 14 6.2 mOdule 2 - user inpuT and frOnT panel funCTiOn Key parameTers () PARAMETER MENU NO FUNCTION With this selection, NO function is performed. This is the factory setting for all user inputs and function keys except the Reset ( RST) Key. NOTE: When a user input is used to accept a quad or directional input signal, then that user input should be programmed for NO function. RESET DISPLAY When activated (momentary action), the shown display is reset. This is the factory setting for the Reset ( RST) Key. EXCHANGE PARAMETER LISTS Two lists of values are available for , , , , , , , , , . The two lists are named and . If a user input is used to select the list then is selected when the user input is not active and and is selected when the user input is active, (maintained action). If a front panel key is used to select the list then the list will toggle for each key press, (momentary action). The meter will suspend ALL operations for approximately 1 msec. while the new values are loaded. The display will only indicate which list is active when the list is changed or when entering any Programming Mode. To program the values for and , first complete the programming of all the parameters. Exit programming and switch to the other list. Re-enter programming and enter the values for , , , , , , , , , . If any other parameters are changed then the other list values must be reprogrammed. PROGRAMMING MODE LOCK-OUT Programming Mode is locked-out, as long as activated (maintained action). In Module 3, certain parameters can be setup where they are still accessible during Programming Mode Lockout. A security code can be configured to allow complete programming access during user input lockout. Function keys should not be programmed for . The meter issues a block print through the serial port when activated. The data transmitted during the print request is configured in Module 7. If the user input is still active after the transmission is complete (about 100 msec.), an additional transmission will occur. Only one transmission will take place with each function key depression. This selection will only function when a serial communications option card is installed in the meter. Module 2 is the programming for rear terminal user inputs and front panel function keys. Three rear terminal user inputs are individually programmable to perform specific meter control functions. While in the Display Mode, the function is executed when the user input transitions to the active state. (Refer to the user input specifications for active state response times.) Certain user input functions are disabled in “full” Programming Mode. Three front panel function F1, F2 and RST keys are also individually programmable to perform specific meter control functions. While in the Display Mode, the primary function is executed when the key is pressed. Holding the F1 and F2 function keys for three seconds executes a secondary function. It is possible to program a secondary function without a primary function. The front panel key functions are disabled in both Programming Modes. In most cases, if more than one user input and/or function key is programmed for the same function, the maintained (level trigger) actions will be performed while at least one of those user inputs or function keys are activated. The momentary (edge trigger) actions are performed every time any of those user inputs or function keys transition to the active state. All functions are available to both user inputs and function keys. Some of the user functions have a sublist of parameters. The sublist is accessed when PAR is pressed at the listed function. The function will only be performed for the parameters entered as . If a user input or function key is configured for a function with a sublist, then that sublist will need to be scrolled through each time to access the following user inputs or function keys parameters. ADVANCE DISPLAY When activated (momentary action), the display advances to the next display that is not locked out from the Display Mode. Shaded parameters do not apply to the PAXR. The meter issues a block print through the serial port when activated just like the Print Request function. In addition, when activated (momentary action), the meter performs a reset of the displays configured as . The print aspect of this action only functions when a serial communication option card is installed. The reset action functions regardless. DISPLAY DESCRIPTION FACTORY Counter A Counter B Counter C Maximum Minimum |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |