16 / 32 page ![]() 16 16 6.3 mOdule 3 - display and prOgram lOCK-OuT parameTers () 3-LOC COdE Lock-out Rate Display Factor x Access Scale Count Load Access Counter x Display Lock-out Counter x Pro Lock-out Min Display Lock-out Max Display Access Setpoint 1-4 Security Code LO HI SP-n CNt PAR rAtE CNtLd SCFAC xx x d-LEV Display Intensity Access PARAMETER MENU x = Counter A , Counter B, and then Counter C n = Setpoints 1 to 4 Module 3 is the programming for Display lock-out and “Full” and “Quick” Program lock-out. When in the Display Mode, the available displays can be read consecutively by repeatedly pressing the DSP key. An annunciator indicates the display being shown. These displays can be locked from being visible. It is recommended that the display be set to when the corresponding function is not used. “Full” Programming Mode permits all parameters to be viewed and modified. This Programming Mode can be locked with a security code and/or user input. When locked and the PAR key is pressed, the meter enters a Quick Programming Mode. In this mode, setpoint, count load, scale factor values, and the Display Intensity Level () parameter can still be read and/or changed per the selections below. COUNTER A B C DISPLAY LOCK-OUT RATE DISPLAY LOCK-OUT MAX. MIN. DISPLAY LOCK-OUT These displays can be programmed for or . to The Count Load Values can be programmed for , , or . The setpoint displays can be programmed for , , or (See the following table). Accessible only with the Setpoint option card installed. COUNT LOAD A B C ACCESS LOCK-OUT The Scale Factor values can be programmed for , , or . SCALE FACTOR A B C ACCESS LOCK-OUT Entry of a non-zero value will cause the prompt to appear when trying to access the “Full” Programming Mode. Access will only be allowed after entering a matching security code or universal code of . With this lock-out, a user input would not have to be configured for Program Lock-out. However, this lock-out is overridden by an inactive user input configured for Program Lock-out. SECURITY CODE SETPOINT 1 to 4 ACCESS LOCK-OUT PROGRAMMING MODE ACCESS SECURITY CODE USER INPUT CONFIGURED USER INPUT STATE WHEN PAR KEY IS PRESSED “FULL” PROGRAMMING MODE ACCESS 0 not ———— “Full” Programming Immediate access. >0 not ———— Quick Programming After Quick Programming with correct code # at prompt. >0 Active Quick Programming After Quick Programming with correct code # at prompt. >0 Not Active “Full” Programming Immediate access. 0 Active Quick Programming No access 0 Not Active “Full” Programming Immediate access. Throughout this document, Programming Mode (without Quick in front) always refers to “Full” Programming (all meter parameters are accessible). Shaded areas represent program access that is model dependent. Shaded areas are model dependent. Not visible in Display Mode Visible in Display Mode DESCRIPTION SELECTION Not visible in Quick Programming Mode Visible and changeable in Quick Programming Mode Visible but not changeable in Quick Programming Mode DESCRIPTION SELECTION The Display Intensity Level can be programmed for , , or . DISPLAY INTENSITY ACCESS LOCK-OUT |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |