91 / 182 page ![]() 78 Fatal Errors (cont’d) Item RUN Auxiliary Area data Corrective action output Error flags Error data Error code Power interruption OFF None A012 to A013 (Power In- terruption Time) A014 (Number of Power Interruptions) None Check the supply voltage, the Power Supply Unit wiring, and the defined power interruption time. Expansion CPU Rack power OFF OFF None None None Turn on the power to the Expan- sion CPU Rack. CPU error OFF None None 80FF Turn the power OFF and ON again. Memory error OFF A40115 ON A403 (Memory Area Er- ror Location) 80F1 Check/correct the program. Cor- rectly mount the Memory Card and Expansion DM Unit. Check the battery connection. Perform the error clear operation after cor- rective actions have been taken. I/O bus error OFF A40114 ON AR404 (I/O Bus Error Rack and Slot Numbers) 80C0- 80C7 (*) 80CE, 80CF Check the cables between the Racks. Perform the error clear op- eration after corrective action has been taken. Duplicated number OFF A40113 ON A409 (Duplicate Rack Number) A410 (CPU Bus Unit Du- plicate Number) 80E9 Set the Rack No. and Unit No. again. Then turn the power OFF and ON again. Perform the error clear operation after corrective action has been taken. CPU bus error OFF A40112 ON A405 (CPU Bus Unit Er- ror Unit Number) 8100- 8115 (**) Check the cables between the CPU Rack and Expansion CPU Rack. Perform the error clear op- eration after corrective actions have been taken. I/O points over OFF A40411 ON A407 (Total I/O Words on CPU and Expansion Racks) A408 (Total SYSMAC BUS/2 I/O Words) A478 (Total SYSMAC BUS I/O Words) 80E1 Read the I/O table to check the number of words allocated. Cor- rect the table if necessary by creating a new one. I/O setting error OFF A40110 ON None 80E0 Verify the I/O table. Correct the table if necessary. Program error OFF A40109 ON None 80F0 Correct the program. Perform the error clear operation after correc- tive actions have been taken. Cycle time over OFF A40108 ON A462/463 (Maximum Cycle Time) A464/465 (Present Cycle Time) 809F Check the program or set time for monitoring the cycle. Fatal SFC error OFF A40107 ON A414 (SFC Fatal Error Code) 80F3 Correct the program. Perform the error clear operation after correc- tive actions have been taken. System failure (FALS) OFF A40106 ON None C101 to C2FF (***) Check/correct the program. Note *0 through 7 indicate rack numbers; E indicates series 0; F indicates series 1. **00 through 15 indicate unit numbers. ***101 through 2FF indicate FALS numbers. Error Messages and Alarm Outputs Section 5-1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |