| Electronic Components Datasheet Search |
|
3G5A2-RPT01-PE Datasheet(PDF) 38 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
3G5A2-RPT01-PE Datasheet(HTML) 38 Page - Omron Electronics LLC |
|
38 / 182 page ![]() 25 2-2-3 Expansion I/O Racks Expansion I/O Racks, shown in the following diagram, can be used to expand the CV-series PCs. There are five models of Expansion I/O Backplane that can be used, as shown in the following table. These vary in the number of slots that they provide for Units (other than the Power Supply Unit and I/O Interface Unit) and in expansion capabilities. CV500 Expansion I/O Backplanes offer complete expansion capabilities, while CVM1 Expansion I/O Backplanes do not support I/O Interface Units and thus must be connected directly to the CPU Backplane (see Single Expansion I/O Rack in this subsection). Expansion I/O Backplane No. of slots I/O Interface Unit CV500-BI042 4 Yes CV500-BI062 6 Yes CV500-BI112 11 Yes CVM1-BI064 6 No CVM1-BI114 11 No An Expansion I/O Rack can be connected either directly to the CPU Backplane (see Single Expansion I/O Rack in this subsection) or to an I/O Control Unit.Up to seven Expansion I/O Racks can be connected to the I/O Control Unit on the CPU Rack in two series unless an Expansion CPU Rack is connected, in which case only six Expansion I/O Racks may be connected. If an Expansion CPU Rack is connected, one of the series of Expansion I/O Racks is connected to the I/O Control Unit on the CPU Rack and the other one is connected to the I/O Interface Unit on the Expansion CPU Rack. Attach a Termination Resistance Unit to the unused terminal on the I/O Interface Unit of the last Expansion I/O Rack in each series. If two series of Expansion I/O Racks are used, connect a Termination Resistance Unit to the last Rack in each. Units (Up to 4/6/11 or the following Units: C500 I/O Units, C500 Special I/O Units, SYSMAC BUS Masters) I/O Connector Connects Expan- sion I/O Rack to preceding Expan- sion I/O, Expansion CPU, or CPU Rack. Termination Resistance Unit A Termination Resistance Unit must be connected to the unused I/O Connecting Cable Connector when an Expansion I/O Rack is not connected. I/O Connector Connects Expan- sion I/O Rack to next Expansion I/O Rack. When not used, connect to a Termination Resistance Unit. I/O Interface Unit (CV500-II201) Connects the Expansion I/O Rack to other Expansion Racks, the CPU Rack, and/or an Expansion I/O Rack. Power Supply Unit CV500-PS221/PS211 or CVM1-PA208 Expansion I/O Backplane CV500-BI042/062/ 112 or CVM1-BI064/114 If only one Expansion I/O Rack is required and no Expansion CPU Rack is used, a single Expansion I/O Rack can be connected directly to the CPU Rack without an I/O Control Unit or I/O Interface Unit. The Racks are connected directly via the connectors on the two Backplanes. Termination Resistance Units are also not required. In every other respect, the Expansion I/O Rack is identical to Expan- sion I/O Racks in connected via I/O Control and I/O Interface Units. Single Expansion I/O Rack Racks Section 2-2 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |