30 / 56 page ![]() ISL8270M FN8635 Rev.4.00 Page 30 of 56 Aug 17, 2017 VOUT_OV_FAULT_LIMIT (40h) Definition: Sets the VOUT overvoltage fault threshold. Data Length in Bytes: 2 Data Format: L16u Type: R/W Default Value: 1.15 x VOUT_COMMAND pin-strap setting Units: V Range: 0V to VOUT_MAX VOUT_OV_FAULT_RESPONSE (41h) Definition: Configures the VOUT overvoltage fault response. Note that the device cannot be set to ignore this fault mode. Data Length in Bytes: 1 Data Format: BIT Type: R/W Default Value: 80h (Disable and no retry) Units: N/A VOUT_OV_WARNING_LIMIT (42h) Definition: Sets the VOUT overvoltage wring threshold. The Power-Good signal is pulled low when output voltage goes higher than this threshold. Data Length in Bytes: 2 Data Format: L16u Type: R/W Default Value: 0.85 x VOUT_COMMAND pin-strap setting Units: V Range: 0V to VOUT_MAX VOUT_UV_WARNING_LIMIT (43h) Definition: Sets the VOUT undervoltage warning threshold. Power-Good signal is pulled low when output voltage goes lower than this threshold. Data Length in Bytes: 2 Data Format: L16u Type: R/W Default Value: 0.85 x VOUT_COMMAND pin-strap setting Units: V Range: 0V to VOUT_MAX VOUT_UV_FAULT_LIMIT (44h) Definition: Sets the VOUT undervoltage fault threshold. This fault is masked during ramp or when disabled. Data Length in Bytes: 2 Data Format: L16u Type: R/W Default Value: 0.85 x VOUT_COMMAND pin-strap setting Units: V Range: 0V to VOUT_MAX BIT FIELD NAME VALUE DESCRIPTION 7:6 Reserved 10 5:3 Retry Setting 000 No retry. The output remains disabled until the fault is cleared. 001-110 Not used. 111 Attempts to restart continuously, without checking if the fault is still present, until it is commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed, or another fault condition causes the unit to shut down. 2:0 Retry Delay 000-111 Retry delay time = (Value + 1) * 35ms. Sets the time between retries in 35ms increments. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |