Back Button ISL8270MEVAL1Z Datasheet HTML 26Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 27Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 28Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 29Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 30Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 31Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 32Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 33Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 34Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 30 / 56 page
background image
ISL8270M
FN8635 Rev.4.00
Page 30 of 56
Aug 17, 2017
VOUT_OV_FAULT_LIMIT (40h)
Definition: Sets the VOUT overvoltage fault threshold.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W
Default Value: 1.15 x VOUT_COMMAND pin-strap setting
Units: V
Range: 0V to VOUT_MAX
VOUT_OV_FAULT_RESPONSE (41h)
Definition: Configures the VOUT overvoltage fault response. Note that the device cannot be set to ignore this fault mode.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W
Default Value: 80h (Disable and no retry)
Units: N/A
VOUT_OV_WARNING_LIMIT (42h)
Definition: Sets the VOUT overvoltage wring threshold. The Power-Good signal is pulled low when output voltage goes higher than this
threshold.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W
Default Value: 0.85 x VOUT_COMMAND pin-strap setting
Units: V
Range: 0V to VOUT_MAX
VOUT_UV_WARNING_LIMIT (43h)
Definition: Sets the VOUT undervoltage warning threshold. Power-Good signal is pulled low when output voltage goes lower than this
threshold.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W
Default Value: 0.85 x VOUT_COMMAND pin-strap setting
Units: V
Range: 0V to VOUT_MAX
VOUT_UV_FAULT_LIMIT (44h)
Definition: Sets the VOUT undervoltage fault threshold. This fault is masked during ramp or when disabled.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W
Default Value: 0.85 x VOUT_COMMAND pin-strap setting
Units: V
Range: 0V to VOUT_MAX
BIT
FIELD NAME
VALUE
DESCRIPTION
7:6
Reserved
10
5:3
Retry Setting
000
No retry. The output remains disabled until the fault is cleared.
001-110
Not used.
111
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed,
or another fault condition causes the unit to shut down.
2:0
Retry Delay
000-111
Retry delay time = (Value + 1) * 35ms. Sets the time between retries in 35ms increments.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com