32 / 56 page ![]() ISL8270M FN8635 Rev.4.00 Page 32 of 56 Aug 17, 2017 OT_FAULT_RESPONSE (50h) Definition: Instructs the device on what action to take in response to an over-temperature fault. Data Length in Bytes: 1 Data Format: BIT Type: R/W Fault Value: 80h (Disable and no retry) Units: N/A OT_WARN_LIMIT (51h) Definition: Sets the temperature at which the device should indicate an over-temperature warning alarm. In response to the OT_WARN_LIMIT being exceeded, the device: Sets the TEMPERATURE bit in STATUS_WORD, sets the OT_WARNING bit in STATUS_TEMPERATURE, and notifies the host. Data Length in Bytes: 2 Data Format: Linear-11. Type: R/W Default Value: EB70h (+110°C) Units: Celsius Range: 0°C to +175°C UT_WARN_LIMIT (52h) Definition: Sets the temperature at which the device should indicate an under-temperature Warning alarm. In response to the UT_WARN_LIMIT being exceeded, the device: Sets the TEMPERATURE bit in STATUS_WORD, sets the UT_WARNING bit in STATUS_TEMPERATURE, and notifies the host. Data Length in Bytes: 2 Data Format: L11. Type: R/W Default Value: DC40h (-30°C) Units: Celsius Range: -55°C to +25°C UT_FAULT_LIMIT (53h) Definition: Sets the temperature, in degrees Celsius, at which the device should indicate an under-temperature fault. Note that the temperature must rise above UT_WARN_LIMIT to clear this fault. Data Length in Bytes: 2 Data Format: L11 Type: R/W Default Value: E530h (-45°C) Units: Celsius Range: -55°C to +25°C BIT FIELD NAME VALUE DESCRIPTION 7:6 Reserved 10 5:3 Retry Setting 000 No retry. The output remains disabled until the fault is cleared. 001-110 Not used. 111 Attempts to restart continuously, without checking if the fault is still present, until it is commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed, or another fault condition causes the unit to shut down. 2:0 Retry Delay 000-111 Retry delay time = (Value + 1) * 35ms. Sets the time between retries in 35ms |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |