Back Button ISL8270MEVAL1Z Datasheet HTML 27Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 28Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 29Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 30Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 31Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 32Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 33Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 34Page - Renesas Technology Corp ISL8270MEVAL1Z Datasheet HTML 35Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 31 / 56 page
background image
ISL8270M
FN8635 Rev.4.00
Page 31 of 56
Aug 17, 2017
VOUT_UV_FAULT_RESPONSE (45h)
Definition: Configures the VOUT undervoltage fault response.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W
Default Value: 80h (Disable, no retry)
Units: N/A
IOUT_OC_FAULT_LIMIT (46h)
Definition: Sets the IOUT average overcurrent fault threshold. Device will automatically calculate peak inductor overcurrent fault limit.
Data Length in Bytes: 2
Data Format: L11
Type: R/W
Default Value: DBC0h (30A)
Units: A
Range: -100A to 100A
IOUT_UC_FAULT_LIMIT (4Bh)
Definition: Sets the IOUT average undercurrent fault threshold. Device will automatically calculate valley inductor undercurrent fault limit.
Data Length in Bytes: 2
Data Format: L11
Type: R/W
Default Value: DC3Fh (-30A)
Units: A
Range: -100A to 100A
OT_FAULT_LIMIT (4Fh)
Definition: Sets the temperature at which the device should indicate an over-temperature fault. Note that the temperature must drop
below OT_WARN_LIMIT to clear this fault.
Data Length in Bytes: 2
Data Format: L11
Type: R/W
Default Value: EBE8h (+125˚C)
Units: Celsius
Range: 0°C to +175°C
BIT
FIELD NAME
VALUE
DESCRIPTION
7:6
Reserved
10
5:3
Retry Setting
000
No retry. The output remains disabled until the fault is cleared.
001-110
Not used.
111
Attempts to restart continuously, without checking if the fault is still present, until it is
commanded OFF (by the CONTROL pin or OPERATION command), bias power is removed,
or another fault condition causes the unit to shut down.
2:0
Retry Delay
000-111
Retry delay time = (Value + 1) * 35ms. Sets the time between retries in 35ms increments.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com