| Electronic Components Datasheet Search |
|
ADFS7124-4BBCPZ Datasheet(PDF) 50 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADFS7124-4BBCPZ Datasheet(HTML) 50 Page - Analog Devices |
|
50 / 93 page ![]() Data Sheet ADFS7124-4 ADC CIRCUIT INFORMATION analog.com Rev. 0 | 50 of 93 Other diagnostics remain active if enabled when the ADC is in the standby mode. Diagnostics can be enabled or disabled while in the standby mode. However, any diagnostics that require the controller clock (reference detect, undervoltage/overvoltage detection, LDO trip tests, memory map CRC, and MCLK counter) must be enabled when the ADC is in the continuous conversion mode or idle mode; these diagnostics do not function if enabled in the standby mode. The standby current is typically 15 µA when the LDOs only are ena- bled. If functions such as the bias voltage generator remain active in the standby mode, the current increases by 36 µA typically. If the internal oscillator remains active in the standby mode, the current increases by 22 µA typically. When exiting the standby mode, the ADFS7124-4 requires 130 MCLK cycles to power up and settle. The internal oscillator, if disabled in the standby mode, requires an additional 40 µs to power up and settle. If an external controller clock is being used, ensure it is active before issuing the command to exit the standby mode. Do not write to the ADC_ CONTROL register again until the ADC has powered up and settled. In the power-down mode, all blocks are powered down, including the LDOs. All registers lose their contents, and the digital outputs P1 and P2 are placed in tristate. To prevent accidental entry to the power-down mode, the ADC must first be placed into the standby mode. If an external controller clock is being used, keep it active until the device is placed in the power-down mode. Exiting the power-down mode requires 64 SCLK cycles with CS = 0 and DIN = 1, that is, a serial interface reset. The ADFS7124-4 requires 2 ms typically to power up and settle. After this time, the user can access the on-chip registers. The power-down current is 2 µA typically. DIGITAL INTERFACE The programmable functions of the ADFS7124-4 are controlled using a set of on-chip registers. Data is written to these registers through the serial interface. Read access to the on-chip registers is also provided by this interface. All communications with the device must start with a write to the communications register. After power- on or reset, the device expects a write to its communications regis- ter. The data written to this register determines whether the next operation is a read operation or a write operation, and determines to which register this read or write operation occurs. Therefore, write access to any of the other registers on the devices begins with a write operation to the communications register, followed by a write to the selected register. A read operation from any other register (except when continuous read mode is selected) starts with a write to the communications register, followed by a read operation from the selected register. The serial interface of the ADFS7124-4 consists of four signals: CS, DIN, SCLK, and DOUT/RDY. The DIN line transfers data into the on-chip registers, whereas DOUT/RDY accesses data from the on-chip registers. SCLK is the serial clock input for the device, and all data transfers (either on DIN or DOUT/RDY) occur with respect to the SCLK signal. The DOUT/RDY pin also operates as a data ready signal; the line goes low when a new data-word is available in the output register. It is reset high when a read operation from the data register is complete. It also goes high before the data register updates to indicate when not to read from the device, to ensure that a data read is not attempted while the register is being updated. CS is used to select a device. It can decode the ADFS7124-4 in systems where several components are connected to the serial bus. Figure 3 and Figure 4 show timing diagrams for interfacing to the ADFS7124-4 with CS decoding the devices. Figure 3 shows the timing for a read operation from the output shift register of the ADFS7124-4. Figure 4 shows the timing for a write operation to the input shift register. A delay is required between consecutive SPI communications. Figure 5 shows the delay required between SPI read/write operations. It is possible to read the same word from the data register several times, even though the DOUT/RDY line returns high after the first read operation. However, care must be taken to ensure that the read operations are complete before the next output update occurs. In the continuous read mode, the data register can be read only once. The serial interface can operate in the 3-wire mode by tying CS low. In this case, the SCLK, DIN, and DOUT/RDY lines communicate with the ADFS7124-4. The end of the conversion can be monitored using the RDY bit in the status register. This scheme is suitable for interfacing to microcontrollers. If CS is required as a decoding signal, it can be generated from a port pin. For microcontroller interfaces, it is recommended that SCLK idle high between data transfers. The ADFS7124-4 can be operated with CS being used as a frame synchronization signal. This scheme is useful for digital signal processing (DSP) interfaces. In this case, the first bit (MSB) is effectively clocked out by CS, because CS normally occurs after the falling edge of SCLK in DSPs. SCLK can continue to run between data transfers, provided the timing numbers are obeyed. CS must be used to frame read and write operations and the CS_EN bit in the ADC_CONTROL register must be set when the diagnostics SPI_READ_ERR, SPI_WRITE_ERR, or SPI_SCLK_CNT_ERR are enabled. The serial interface can be reset by writing a series of 1s on the DIN input. See the Reset section for more details. Reset returns the interface to the state in which it is expecting a write to the communications register The ADFS7124-4 can be configured to continuously convert or perform a single conversion (see Figure 78 through Figure 80). Single Conversion Mode In the single conversion mode, the ADFS7124-4 performs a single conversion and is placed in the standby mode after the conversion is complete. If a controller clock is present (external controller clock or the internal oscillator is enabled), DOUT/RDY goes low to indi- cate the completion of a conversion. When the data-word is read |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |