| Electronic Components Datasheet Search |
|
H7CX-ASD Datasheet(PDF) 17 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-ASD Datasheet(HTML) 17 Page - Omron Electronics LLC |
|
17 / 43 page ![]() Multifunction Preset Counter H7CX C-103 Precautions !Caution Do not use the product in locations subject to flammable or explo- sive gases. Doing so may result in explosion. The service life of the output relays depends on the switching capacity and switching conditions. Consider the actual application conditions and use the product within the rated load and electrical service life. Using the product beyond its service life may result in contact deposition or burning. Do not disassemble, repair, or modify the product. Doing so may result in electric shock, fire, or malfunction. Do not allow metal objects or conductive wires to enter the product. Doing so may result in electric shock, fire, or malfunction. I External Power Supply The capacity of the external power supply is 100 mA at 12 V. When using a 24 VAC/12 to 24 VDC power supply, reduce the load with the power supply voltage, as shown in the following diagram (DC power supplies only). I Power Supplies When turning the power ON and OFF, input signal reception is possi- ble, unstable, or impossible as shown in the diagram below. Turn the power ON and OFF using a relay with a rated capacity of 10 A minimum to prevent contact deterioration due to inrush current caused by turning the power ON and OFF. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately, otherwise they may not be reset or a counter error may result. Be sure that the capacity of the power supply is large enough, other- wise the counter may not start due to inrush current (reference value: approx. 10 A, 1.2 ms at 26.4 VAC) that may flow for an instant when the counter is turned ON. Make sure that the fluctuation of the supply voltage is within the per- missible range. Make sure that the voltage applied is within the specified range, oth- erwise the internal elements of the counter may be damaged. I Transistor Output The transistor output of the H7CX is isolated from the internal cir- cuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. The diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the H7CX. I Changing the Set Values When changing the set value during operation, because the H7CX uses a constant read-in system, output will turn ON if the set value is equal to the present value. I Operation with a Set Value and Present Value of 0 If the set value and present value are both 0, output will turn ON. Output will turn OFF during reset. I Using the Prescaling Function Observe the following points when setting a prescale value. • Set the set value to a value less than {Maximum countable value − Prescale value}. Example: If the prescale value is 1.25 and the counting range is 0.000 to 999.999, set the set value to a value less than 998.749 (= 999.999 − 1.25). • If the set value is set to a value greater than this, output will not turn ON. Note: Output will turn ON, however, if a present value overflow occurs (FFFFFF or FFFF). • Setting the prescale value incorrectly may result in incorrect count- ing operation. Be sure to set the prescale value correctly. I DIP Switch Setting Ensure that the power is turned OFF before changing DIP switch set- tings. Changing DIP switch settings with the power turned ON may result in electric shock due to contact with terminals subject to high voltages. I Power Failure Backup All data is stored in the EEPROM when there is power failure. The EEPROM can be overwritten more than 100,000 times. EEPROM is overwritten when the power is turned OFF or when settings are changed. 10.8 15 100 20 Power pply vol age C) (DC v ltage ppl only) 200 ms 5 ms ON OFF Input Impossible Unstable Possible Unstable Impossible 0 to 1 s 0 to 90 ms Power supply + + Power for load Power for load Load Load NPN output PNP output + Counter Power for load Inductive load |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |