| Electronic Components Datasheet Search |
|
H7CX-ASD Datasheet(PDF) 27 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-ASD Datasheet(HTML) 27 Page - Omron Electronics LLC |
|
27 / 43 page ![]() Multifunction Preset Counter H7CX (Counter Function) C-113 Input/Output Mode Settings Operation for 1-stage models is the same as that for OUT2. When using a 2-stage model as a 1-stage counter, total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF simulta- neously. Note: 1. The full scale (FS) for H7CX 4-digit models is 9999. 2. When the present value reaches 999999, it returns to 0. 3. Counting cannot be performed during reset/reset 1 input. 4. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF. 5. If there is power failure while output is ON, output will turn ON again when the power supply has recovered. For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered. 6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON. One-shot output from OUT1 Self-holding output Self-holding output One-shot output from OUT2 (The one-shot output time can be set in the range 0.01 to 99.99s.) Input mode Operation after count completion UP DOWN UP/DOWN A, B, C Output mode setting N The outputs and present value display are held until reset/re- set 1 is input. F The present value dis- play continues to in- crease/decrease. The outputs are held until reset/reset 1 is input. C As soon as the count reaches SV, the present value display returns to the reset start status. The present value dis- play does not show the present value upon count-up. The outputs repeat one-shot operation. OUT1 self-holding out- put turns OFF after the OUT2 one-shot output time.The OUT1 one- shot output time is inde- pendent of OUT2. R The present value dis- play returns to the reset start status after the one-shot output time. The outputs repeat one-shot operation. OUT1 self-holding out- put turns OFF after the OUT2 one-shot output time.The OUT1 one- shot output time is inde- pendent of OUT2. 999999 0 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 999999 0 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 999999 0 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 999999 0 OUT1 OUT2 Reset/ reset 1 Set value 2 Set value 1 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |