H7CX-ASD Datasheet(PDF) 22 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
H7CX-ASD Datasheet(HTML) 22 Page - Omron Electronics LLC |
|
22 / 43 page ![]() C-108 Multifunction Preset Counter H7CX (Counter Function) Settings for All Functions Note: At the time of delivery, the H7CX is set to the 1-stage counter (2-stage counter for H7CX-AW @/-A4W@ models) configuration. When using as a 2-stage (or 1-stage) counter, total and preset counter, batch counter, or dual counter, switch to the configuration using the procedure given on page 124. (1ms) (20ms) (30Hz) (5kHz) (N) (0.50s) (99.99s) (0.01s) (0.50s) (99.99s) (0.01s) (0.01s) (99.99s) (F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H) (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) (99.999) [9.999] (1.000) (0.001) (0.50s) (99.99s) (0.01s) ∼ ∼ The characters displayed in reverse video are the default settings. Power ON Note 4: Displayed for output modes other than K-2, D, L, and H only. Input mode Output mode Display color See note 1. See note 2. For details on operations in run mode, refer to page 25. 3 s min. 3 s min. When using as a 2-stage counter: (Addition) (Subtraction) (Outputs held) See note 7. See note 3. See note 6. See note 5. See note 4. See note. See note 4. See note 5. See note 5. See note 5. Note: Displayed for terminal-block models (except H7CX-A11 @) only. (Red) (Green) (Red-green) (Green-red) Settings that cannot be performed with the DIP switch are performed with the operation keys. When using as a dual counter: Note 3: Note 6: See note 7. Note: Displayed for H7CX-AU @ models only. Note: 1. If the mode is switched to the function setting mode during operation, operation will con- tinue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the counter is reset (present value initialized and output turned OFF) on returning to run mode. When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed. Key protect level Output allocation NPN/PNP input mode Prescale value Decimal point position Reset input signal width Counting speed One-shot output time (UP) (DOWN) (UP/DOWN A) (UP/DOWN B) (UP/DOWN C) Dual count calculating mode Note: Displayed for output modes other than K-2, D, L, and H only. Note: 5. Display only when the input mode is UP/DOWN A, B, or C with 6-digit models (with H7CX-AU @/-AW@ models only for H). One- shot output 2 time One- shot output 1 time One- shot output 2 time Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. If the output time is 0.00, hold is displayed. Note 1: Displayed for output modes other than D, L, and H. Note 2: HOLD cannot be set when the output mode is K-2. Note: Displayed only when the output mode is C, R, K-1, P, Q, A, or K-2. When using as a batch counter: No decimal point One digit after decimal point Two digits after decimal point Three digits after decimal point Note 7: The displays for 4-digit models are shown inside parentheses. (NPN input) (PNP input) Set each setting item using the keys. ( key only for 6-digit models) r |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |