29 / 59 page ![]() HT82K70E-L/HT82K70A-L/HT82K76E-L Rev. 1.20 29 February 1, 2011 Standby Current Considerations As the main reason for entering the Power Down Mode is to keep the current consumption of the microcontroller to as low a value as possible, perhaps only in the order of several micro-amps, there are other considerations which must also be taken into account by the circuit de- signer if the power consumption is to be minimised. Special attention must be made to the I/O pins on the device. All high-impedance input pins must be con- nected to either a fixed high or low level as any floating input pins could create internal oscillations and result in increased current consumption. Care must also be taken with the loads, which are connected to I/O pins, which are setup as outputs. These should be placed in a condition in which minimum current is drawn or con- nected only to external circuits that do not draw current, such as other CMOS inputs. If the configuration options have enabled the Watchdog Timer internal oscillator then this will continue to run when in the Power Down Mode and will thus consume some power. For power sensitive applications it may be therefore preferable to use the system clock source for the Watchdog Timer. Wake-up After the system enters the Power Down Mode, it can be woken up from one of various sources listed as follows: · An external reset · An external falling edge on any of the I/O pins · A system interrupt · A WDT overflow If the system is woken up by an external reset, the de- vice will experience a full system reset, however, if the device is woken up by a WDT overflow, a Watchdog Timer reset will be initiated. Although both of these wake-up methods will initiate a reset operation, the ac- tual source of the wake-up can be determined by exam- ining the TO and PDF flags. The PDF flag is cleared by a system power-up or executing the clear Watchdog Timer instructions and is set when executing the ²HALT² instruction. The TO flag is set if a WDT time-out occurs, and causes a wake-up that only resets the Program Counter and Stack Pointer, the other flags remain in their original status. Configuration options determine which pin or groups of pins can be setup to permit a negative transition on the pin to wake-up the system. When a Port pin wake-up oc- curs, the program will resume execution at the instruc- tion following the ²HALT² instruction. When a PA0/PA1 or PB0/PB1 wake up occurs, bits in the WSR register can be read to know which pin changed first. If the system is woken up by an interrupt, then two possi- ble situations may occur. The first is where the related interrupt is disabled or the interrupt is enabled but the stack is full, in which case the program will resume exe- cution at the instruction following the ²HALT² instruction. In this situation, the interrupt which woke-up the device will not be immediately serviced, but will rather be ser- viced later when the related interrupt is finally enabled or when a stack level becomes free. The other situation is where the related interrupt is enabled and the stack is not full, in which case the regular interrupt response takes place. If an interrupt request flag is set to ²1² be- fore entering the Power Down Mode, the wake-up func- tion of the related interrupt will be disabled. No matter what the source of the wake-up event is, once a wake-up situation occurs, a time period equal to 1024 system clock periods will be required before normal sys- tem operation resumes. However, if the wake-up has originated due to an interrupt, the actual interrupt sub- routine execution will be delayed by an additional one or more cycles. If the wake-up results in the execution of the next instruction following the ²HALT² instruction, this will be executed immediately after the 1024 system clock period delay has ended. Low Voltage Detector - LVD The Low Voltage Detector internal function provides a means for the user to monitor when the power supply voltage falls below a certain fixed level as specified in the DC characteristics. Operation The LVD enable/disable control bit is bit 4 of the CTLR register. Under normal operation, and when the power supply voltage is above the specified VLVD value, spec- ified by the LVD_sel bits in the CTLR register, the Low battery bit will remain at a zero value. If the power supply voltage should fall below this VLVD value then the Low battery bit will change to a high value indicating a low voltage condition. Note that the Low battery bit is a read-only bit. By polling the Low battery bit in the CTLR register, the application program can therefore deter- mine the presence of a low voltage condition. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |