| Electronic Components Datasheet Search |
|
ST25R3918 Datasheet(PDF) 58 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25R3918 Datasheet(HTML) 58 Page - STMicroelectronics |
|
58 / 142 page ![]() Application information ST25R3918 58/142 DS13490 Rev 1 4.4.6 Mask receive data and Unmask receive data The direct command Mask receive data disables processing of the receiver output by the RX decoders, RSSI measurement, and AGC operation. The direct command Unmask receive data enables processing of the received data by the RX decoders, RSSI measurement and AGC operation. A common use of this command is to re-enable the receiver operation after it was masked by the command Mask receive data. If the Mask receive timer is still running while the direct command Unmask receive data is received, reception is enabled, and the Mask receive timer is reset. In passive target (card emulation) mode, the Unmask receive data command prepares the RX decoders for a new data reception and clears the internal FDT timer. In passive target mode, this direct command must be used only if no further transmission from the ST25R3918 is planned and the device has to wait for the next command to be received. 4.4.7 Change AM modulation state This command changes the AM modulation state from unmodulated to modulated, and vice versa. This can be used to measure the AM modulation index with the direct command Measure amplitude. The command only affects the regulator state and not the resistive modulation state. 4.4.8 Measure amplitude This command measures the amplitude of the RF signal on the RFI inputs and stores the result in the A/D converter output register. This command enables the transmitter and amplitude detector. The transmitter drives the antenna, and the amplitude detector converts the differential RF signal received back between RFI1 and RFI2 into a proportional DC voltage. This DC voltage is converted with the A/D converter in absolute conversion mode into an 8-bit value and stored in the A/D converter output register. The amplitude detector conversion gain is 0.6 VinPP / Vout referenced to the RF signal on a single RFI pin. Thus, one LSB of the A/D converter output represents 13.02 mVPP on either of the RFI inputs. Note: The maximum allowed voltage level on an RFI pin is 3 VPP. This results in 1.8 V output DC voltage of the amplitude detector and produces a value of E6h after A/D conversion. Duration time: 25 μs max. RF waiting time TRFW 512 / fc n = 0…3 based on nfc_n<1:0> in Auxiliary definition register Active guard time TARFG 75 µs + NFC field on guard time s NFC Field ON guard time defined in the NFC field on guard timer register. NFCPIP-1 TARFG requirement: > 75 µs + NFC field ON guard times (1024 / fc) Table 12. Timing parameters of NFC field ON commands (continued) Parameter Symbol Value Unit Notes |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |