| Electronic Components Datasheet Search |
|
DFE252012P-2R2M Datasheet(PDF) 27 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
DFE252012P-2R2M Datasheet(HTML) 27 Page - Microchip Technology |
|
27 / 44 page ![]() 2020 Microchip Technology Inc. DS20006388A-page 27 MCP16501 4.5 Configuration Options The device variants highlighted in Section 4.0 “Device Options” are generated at the factory with One-Time-Programmable memory, which configures default settings at power-up. To accommodate future possible MPUs or application architectures the following configurations can be taken into account to define other device options. TABLE 4-5: DEVICE CONFIGURATION Note 1: [1,2,3]-refers to each individual Buck channel setting Note: Please contact your nearest Microchip Sales Office for further assistance on the development of customized device vari- ants. Setting Description RSTDLY nRSTO assertion delay (t4 in the start-up sequence); options are: 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms and 128 ms; default is 16 ms AWKPDIS Enables or disables the automatic wake-up pulse; default is enabled VOUT[1,2,3] Buck output voltage, Buck1 output range is between 1.2V and 3.7V with a 50 mV resolution, while Buck2 and Buck3 have an output range between 0.6V and 1.85V with a 25mV resolu- tion EN[1,2,3] Enables or disables each Buck converters for all individual power state MODE[1,2,3] FPWM or Auto PFM for each Buck converters for all individual power state SSR[1,2,3] Soft Start rate for Buck converters; options are: 3.125 V/ms, 1.563 V/ms, 1.042 V/ms and 0.781 V/ms; default is 3.125 V/ms SEQ[1,2,3] Startup sequence step for each Buck converter DELAY[1,2,3] Time delay from the completion of the previous Start-Up Sequence Step or Start-Up Event to the turn-on (beginning of Soft Start); options are:0ms, 0.5ms, 1ms, 2 ms, 4 ms, 8 ms, 12 ms, 16 ms B1HCEN Enables or disables the Hysteretic Control Mode for Buck1 in AutoPFM operation; only enabled for MCP16501E HCPEN[1,2,3] Enables or disables the Hiccup short-circuit protection for each Buck converter; default is enabled with the exception of MCP16501D. When disabled, a short circuit will cause the immediate turn-off of all channels followed by a 100 ms wait time and an automatic restart sequence. DISCH[1,2,3] Enables or disables the active output discharge when the channel is turned off; default is enabled PHASE[1,2,3] Enables operation 180° out of phase with the oscillator for each Buck |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |