| Electronic Components Datasheet Search |
|
ST25R3920B Datasheet(PDF) 64 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25R3920B Datasheet(HTML) 64 Page - STMicroelectronics |
|
64 / 158 page ![]() Application information ST25R3920B 64/158 DS13890 Rev 4 Duration time: 5 ms max. This command is not accepted if external definition of the regulated voltage is selected in the Regulator voltage control register (bit reg_s is set to 1). 4.4.11 Measure phase This command measures the phase difference between the signals on the RFO outputs and the signals on the RFI inputs and stores the result in the A/D converter output register. This command enables the transmitter and phase detector, and performs an A/D conversion of the output of the phase detector with the A/D converter in relative mode. The phase measurement results can be calculated using the following formulas: • 0 ≤ Φ ≤ 17º: result = 255 • 17 < Φ < 163º: angle [º] = 17 + (1 -result / 255) * 146 • 163 ≥ Φ ≥ 180º: result = 0 Duration time: 25 μs max. 4.4.12 Clear RSSI The receiver automatically clears the RSSI bits in the RSSI display register and starts a new measurement of the RSSI when a new reception is started (e.g. after a Transmit direct command). Since the RSSI bits store the peak value (peak-hold type) eventual variation of the receiver input signal will not be followed (this may happen in case of a long message or test procedure). The direct command Clear RSSI clears the RSSI bits in the RSSI display register, and restarts the RSSI measurement. This allows to obtain multiple RSSI measurements during a single reception. 4.4.13 Transparent mode This command sets the receiver and transmitter into the transparent mode. The device enters the transparent mode on the rising edge of the BSS signal of the SPI frame used to send the direct command. The transparent mode is maintained as long as signal BSS is kept high, that is, the following SPI command sent from the microcontroller will automatically stop the transparent mode. 4.4.14 Measure power supply This command measures the power supply. The bits mpsv<2:0> in the Regulator voltage control register select which signal is measured. The result of the measurement is stored in the A/D converter output register. For power supply measurements the selected supply input voltage is divided by three and measured with the A/D converter in absolute mode. This leads to a resolution of 23.4 mV per LSB for all power supply measurements. Duration time: 25 μs max. 4.4.15 Trigger RC calibration The command triggers the RC calibration cycle for the active waveshaping filter constant. The result can be read in AWS time 6 register and IRQ I_dct signals end of calibration. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |