| Electronic Components Datasheet Search |
|
AS7058 Datasheet(PDF) 52 Page - ams-OSRAM AG |
|
|
|||||||||||||||||||||||||||||
AS7058 Datasheet(HTML) 52 Page - ams-OSRAM AG |
|
52 / 199 page ![]() AS7058 Functional description Datasheet • PUBLIC • Document Feedback DS001077 • v2-00 • 2025-Sep-24 52 / 199 / The chosen mode influences which excitation waveform, sine wave for the BioZ, and square wave for GSR, is used. Furthermore, the applied current range and excitation frequency are different. The choice between the two modes can be done in BIOZ_CFG register (see chapter 8.1 Register overview). Important to mention is that BIOZ_EN and GSR_EN must not be set to 1 at the same time. When BioZ is activated, the excitation frequency can be chosen in steps from 1 kHz to 1 MHz on a sine waveform, and the current can be controlled from 10 µA to 100 µA. These settings can be chosen in BIOZ_EXCIT register. The settings will only be applied when BIOZ_EN bit is set to one. The operating gain of the BioZ/GSR preamplifier can also be extended to gain 2 via register bit BIOZ_GAIN. When GSR is activated, the excitation frequency is half of the ECG sample frequency chosen in a square waveform, and the current can be controlled from 200 nA to 85 µA. These settings can be chosen in BIOZ_EXCIT. The settings will only be applied when GSR_EN bit is set to one. The dynamic range that can be achieved is between 300 nS to 100 µS with 1 nS step size. 7.7.3 ECG/BioZ signal processing overview Similar to the PPG signal processing the ECG and BioZ data acquisition path supports also various signal processing options. An overview of all options and a device signal flow is shown in Figure 45. The output of ADC modulator 3 is connected to the SINC filter block which acts as down sampling filter. It is possible to select between 4th and 5th filter order via register ECG1_SEL_ORDER and ECG2_SEL_ORDER as well as decimation rates between 16, 32, 64, 128 and 256 via register ECG1_SINC_DEC and ECG2_SINC_DEC. In order to further improve SNR of the system there is an oversampling filter function, which is part of the down sampling filter that can be enabled via register ECG1_SINC_OVS and ECG2_SINC_OVS. The three-bit register allows for 7 different oversampling filter ratios to be enabled from factor 2 up to 128. The oversampling filter function is disabled in default configuration. Please mind that by enabling the oversampling filter function the active ADC modulator time is increased influencing power consumption with the benefit of better noise behavior. Once the signal passed the SINC decimation and optional oversampling filter the ECG/BioZ signal is feed into a scaling block which converts the signal into 20-bit unsigned signal. The on-chip IIR filter block is the last processing block which can be enabled to implement post processing filter characteristics before the data is written to the FIFO memory. Please refer to chapter 7.8 for more detail information regarding the IIR filter block. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |