29 / 37 page ![]() Data Sheet ADIS16475 Rev. D | Page 29 of 37 Data Update Rate in External Sync Modes When using the input sync option, in scaled sync mode (Register MSC_CTRL, Bits[4:2] = 010, see Table 105), the output data rate is equal to (fSYNC × KECSF)/(DEC_RATE + 1) where: fSYNC is the frequency of the clock signal on the SYNC pin. KESCF is the value from the UP_SCALE register (see Table 107). When using direct sync mode and pulse sync mode, KESCF = 1. Continuous Bias Estimation (NULL_CNFG) Table 110. NULL_CNFG Register Definition Addresses Default Access Flash Backup 0x66, 0x67 0x070A R/W Yes Table 111. NULL_CNFG Bit Definitions Bits Description [15:14] Not used 13 Z-axis accelerometer bias correction enable (1 = enabled) 12 Y-axis accelerometer bias correction enable (1 = enabled) 11 X-axis accelerometer bias correction enable (1 = enabled) 10 Z-axis gyroscope bias correction enable (1 = enabled) 9 Y-axis gyroscope bias correction enable (1 = enabled) 8 X-axis gyroscope bias correction enable (1 = enabled) [7:4] Not used [3:0] Time base control (TBC), range: 0 to 12 (default = 10); tB = 2TBC/2000, time base; tA = 64 × tB, average time The NULL_CNFG register (see Table 110 and Table 111) provides the configuration controls for the continuous bias estimator (CBE), which associates with the bias correction update command in Register GLOB_CMD, Bit 0 (see Table 113). Register NULL_ CNFG, Bits[3:0], establishes the total average time (tA) for the bias estimates and Register NULL_CNFG, Bits[13:8], provide the on/off controls for each sensor. The factory default configuration for the NULL_CNFG register enables the bias null command for the gyroscopes, disables the bias null command for the accelerometers, and sets the average time to ~32 sec. Global Commands (GLOB_CMD) Table 112. GLOB_CMD Register Definition Addresses Default Access Flash Backup 0x68, 0x69 Not applicable W No Table 113. GLOB_CMD Bit Definitions Bits Description [15:8] Not used 7 Software reset [6:5] Not used 4 Flash memory test 3 Flash memory update 2 Sensor self test 1 Factory calibration restore 0 Bias correction update The GLOB_CMD register (see Table 112 and Table 113) provides trigger bits for several operations. Write a 1 to the appropriate bit in GLOB_CMD to start a particular function. During the execution of these commands, data production stops, pulsing stops on the DR pin, and the SPI interface does not respond to requests. Table 1 provides the execution time for each GLOB_CMD command. Software Reset Use the following DIN sequence to set Register GLOB_CMD, Bit 7 = 1, which triggers a reset: 0xE880, then 0xE900. This reset clears all data, and then restarts data sampling and processing. This function provides a firmware alternative to toggling the RST pin (see Table 5, Pin F3). Flash Memory Test Use the following DIN sequence to set Register GLOB_CMD, Bit 4 = 1, which tests the flash memory: 0xE810, then 0xE900. The command performs a CRC computation on the flash memory (excluding user register locations) and compares it to the original CRC value, which comes from the factory configuration process. If the current CRC value does not match the original CRC value, Register DIAG_STAT, Bit 6 (see Table 10), rises to 1, indicating a failing result. Flash Memory Update Use the following DIN sequence to set Register GLOB_CMD, Bit 3 = 1, which triggers a backup of all user configurable registers in the flash memory: 0xE808, then 0xE900. Register DIAG_ STAT, Bit 2 (see Table 10), identifies success (0) or failure (1) in completing this process. Sensor Self Test Use the following DIN sequence to set Register GLOB_CMD, Bit 2 = 1, which triggers the self test routine for the inertial sensors: 0xE804 and 0xE900. The self test routine uses the following steps to validate the integrity of each inertial sensor: 1. Measure the output on each sensor. 2. Activate an internal stimulus on the mechanical elements of each sensor to move them in a predictable manner and create an observable response in the sensors. 3. Measure the output response on each sensor. 4. Deactivate the internal stimulus on each sensor. 5. Calculate the difference between the sensor measurements from Step 1 (stimulus is off) and from Step 3 (stimulus is on). 6. Compare the difference with internal pass and fail criteria. 7. Report the pass and fail result to Register DIAG_STAT, Bit 5 (see Table 10). Motion during the execution of this test can indicate a false failure. Factory Calibration Restore Use the following DIN sequence to set Register GLOB_CMD, Bit 1 = 1, to restore the factory default settings for the MSC_ CTRL, DEC_RATE, and FILT_CTRL registers and to clear all user configurable bias correction settings: 0xE802, then 0xE900. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |