| Electronic Components Datasheet Search |
|
ADIS16475-1/PCBZ Datasheet(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADIS16475-1/PCBZ Datasheet(HTML) 19 Page - Analog Devices |
|
19 / 37 page ![]() Data Sheet ADIS16475 Rev. D | Page 19 of 37 USER REGISTER DEFINTIONS Status/Error Flag Indicators (DIAG_STAT) Table 9. DIAG_STAT Register Definition Addresses Default Access Flash Backup 0x02, 0x03 0x0000 R No Table 10. DIAG_STAT Bit Assignments Bits Description [15:8] Reserved. 7 Clock error. A 1 indicates that the internal data sampling clock (fSM, see Figure 19 and Figure 20) does not synchronize with the external clock, which only applies when using scaled sync mode (Register MSC_CTRL, Bits[4:2] = 010, see Table 105). When this error occurs, adjust the frequency of the clock signal on the SYNC pin to operate within the appropriate range. 6 Memory failure. A 1 indicates a failure in the flash memory test (Register GLOB_CMD, Bit 4, see Table 113), which involves a comparison between a cyclic redundancy check (CRC) calculation of the present flash memory and a CRC calculation from the same memory locations at the time of initial programming (during the production process). If this error occurs, repeat the same test. If this error persists, replace the ADIS16475 device. 5 Sensor failure. A 1 indicates failure of at least one sensor, at the conclusion of the self test (Register GLOB_CMD, Bit 2, see Table 113). If this error occurs, repeat the same test. If this error persists, replace the ADIS16475. Motion during the execution of this test can cause a false failure. 4 Standby mode. A 1 indicates that the voltage across VDD and GND is <2.8 V, which causes data processing to stop. When VDD ≥ 2.8 V for 250 ms, the ADIS16475 reinitializes itself and starts producing data again. 3 SPI communication error. A 1 indicates that the total number of SCLK cycles is not equal to an integer multiple of 16. When this error occurs, repeat the previous communication sequence. Persistence in this error may indicate a weakness in the SPI service that the ADIS16475 is receiving from the system it is supporting. 2 Flash memory update failure. A 1 indicates that the most recent flash memory update (Register GLOB_CMD, Bit 3, see Table 113) failed. If this error occurs, ensure that VDD ≥ 3 V and repeat the update attempt. If this error persists, replace the ADIS16475. 1 Data path overrun. A 1 indicates that one of the data paths experienced an overrun condition. If this error occurs, initiate a reset using the RST pin (see Table 5, Pin F3) or Register GLOB_CMD, Bit 7 (see Table 113). See the Serial Port Operation section for more details on conditions that may cause this bit to be set to 1. 0 Reserved. The DIAG_STAT register (see Table 9 and Table 10) provides error flags for monitoring the integrity and operation of the ADIS16475. Reading this register causes all of its bits to return to 0. The error flags in DIAG_STAT are sticky, meaning that, when they raise to a 1, they remain there until a read request clears them. If an error condition persists, the flag (bit) automatically returns to an alarm value of 1. GYROSCOPE DATA The gyroscopes in the ADIS16475 measure the angular rate of rotation around three orthogonal axes (x, y, and z). Figure 36 shows the orientation of each gyroscope axis, along with the direction of rotation that produces a positive response in each of their measurements. ωZ ωY Y ωX Z X PIN A8 PIN K1 Figure 36. Gyroscope Axis and Polarity Assignments Each gyroscope has two output data registers. Figure 37 shows how these two registers combine to support a 32-bit, twos complement data format for the x-axis gyroscope measurements. This format also applies to the y- and z-axes. Additional information on the precision and resolution of the accelerometers can be found in the Digital Resolution of Gyroscopes and Accelerometers section of this data sheet. X-AXIS GYROSCOPE DATA X_GYRO_OUT X_GYRO_LOW BIT 0 BIT 15 BIT 15 BIT 0 Figure 37. Gyroscope Output Data Structure Gyroscope Measurement Range/Scale Factor Table 11 provides the measurement range (±ωMAX) and scale factor (KG) for the gyroscope in each ADIS16475 model. Table 11. Gyroscope Measurement Range and Scale Factors Model Range, ±ωMAX (°/sec) Scale Factor, KG (LSB/°/sec) ADIS16475-1 ±125 160 ADIS16475-2 ±500 40 ADIS16475-3 ±2000 10 Gyroscope Data Formatting Table 12 and Table 13 offer various numerical examples that demonstrate the format of the rotation rate data in both 16-bit and 32-bit formats. Table 12. 16-Bit Gyroscope Data Format Examples Rotation Rate Decimal Hex Binary +ωMAX +20,000 0x4E20 0100 1110 0010 0000 +2/KG +2 0x0002 0000 0000 0000 0010 +1/KG +1 0x0001 0000 0000 0000 0001 0°/sec 0 0x0000 0000 0000 0000 0000 −1/KG −1 0xFFFF 1111 1111 1111 1111 −2/KG −2 0xFFFE 1111 1111 1111 1110 −ωMAX −20,000 0xB1E0 1011 0001 1110 0000 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |