67 / 82 page ![]() NXP Semiconductors SL2S3003/SL2S3003TT ICODE 3 (TagTamper) 8.5.3.25 24-bit counter Block 75 of the user memory contains the 24-bit counter. The block can be accessed with the standard READ and WRITE commands but special data considerations are required. The standard password protection mechanisms for the user memory are not valid for block 75. The 24-bit counter (block 75) can be: • Read. • Increased by one with the option of read password protection. • Preset to the initial start value with the write password protection. The counter can be read with any read command including block 75. The 4-byte data from block 75 provide the following information: Byte Name Value Description 0 C0 0x00 - 0xFF LSB of the counter value 1 C1 0x00 - 0xFF — 2 C2 0x00 - 0xFF MSB of the counter value 0x00 Incrementing of the counter value is not password protected 3 PROT 0x01 Incrementing of the counter value is protect with the read password Table 132. COUNTER BLOCK data structure The counter can be preset to a start value with a WRITE SINGLE BLOCK command to block 75. As the counter preset is password protected with the write password, a SET PASSWORD command with the write password is required before executing the Preset (refer to Section 8.5.3.2 "SET PASSWORD"). The PROT byte (data byte 3) value defines whether the password protection to increment the counter is enabled or disabled. If the password protection is enabled, the read password is required to increment the counter value. The data for the WRITE SINGLE BLOCK command to preset the counter are defined in Table 133. Note: The Preset counter value of 0x0001 is not possible. A WRITE SINGLE BLOCK command with 0x0001 value only increments the counter. Byte Name Value Description 0 C0 0x00, 0x02 - 0xFF LSB of the counter value 1 C1 0x00 - 0xFF — 2 C2 0x00 - 0xFF MSB of the counter value 0x00 Disable the password protection to increment the counter 3 PROT 0x01 Enable the password protection to increment the counter with read password Table 133. Preset counter data structure SL2S3003/SL2S3003TT All information provided in this document is subject to legal disclaimers. © 2024 NXP B.V. All rights reserved. Product data sheet Rev. 3.0 — 28 March 2024 67 / 82 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |