20 / 32 page ![]() EVAL-AD5933EB Preliminary Technical Data Rev. PrC | Page 20 of 32 The gain factor is then given by GAIN FACTOR CALCULATION Magnitude Magnitude Impedance Code Admittance Factor Gain ⎟ ⎟ ⎠ ⎞ ⎜ ⎜ ⎝ ⎛ = ⎟⎟ ⎠ ⎞ ⎜⎜ ⎝ ⎛ = ⎟ ⎠ ⎞ ⎜ ⎝ ⎛ = kΩ 100 1 1 The code in the Evaluation Board Source Code Extract section for the impedance sweep is based on a single-point gain factor calculation, which is determined at the midpoint sweep frequency with a known impedance connected between VOUT and VIN. The gain factor for this example is calculated by exciting the calibration impedance using a 2 V p-p sinusoid with a frequency of 30.750 kHz, a PGA setting of ×1, a 100 kΩ resistor connected between VOUT and VIN, and a feedback resistor of 100 kΩ. The magnitude of the real and imaginary components at the calibration frequency is given by the formula: Refer to the AD5933 data sheet for more details. TEMPERATURE MEASUREMENT The temperature sensor data is stored in a 14-bit, twos complement format. For the conversion formula and more details on the temperature sensor, see the AD5933 data sheet. 2 2 I R Magnitude + = where R is the real component, and I is the imaginary component of the calibration code. Private Sub MeasureTemperature() ' The Digital temperature Result is stored over two registers as a 14 bit twos complement number. ' 92H <D15-D8> and 93H<D7 to D0>. Dim TemperatureUpper As Long. Dim TemperatureLower As Long 'Write xH90 to the control register to take temperature reading. WritetToPart &H80, &H90 msDelay 5 'nominal delay ReadbackStatusRegister = PortRead(&HD, &H8F) ReadbackStatusRegister = ReadbackStatusRegister And &H1 'if a valid temperature conversion is complete, ignore this. If ReadbackStatusRegister <> 1 Then 'loop to wait for temperature measurement to complete. Do ReadbackStatusRegister = PortRead(&HD, &H8F) ReadbackStatusRegister = ReadbackStatusRegister And &H1 Loop Until (ReadbackStatusRegister = 1) Form1.Label10.Caption = "Current Device Temperature" MsgBox "Device Temperature Measurement Complete" End If ' The Digital temperature Result is stored over two registers as a 14 bit twos complement number. ' 92H <D15-D8> and 93H<D7 to D0>. TemperatureUpper = PortRead(&HD, &H92) TemperatureLower = PortRead(&HD, &H93) Temperature = TemperatureLower + (TemperatureUpper * 256) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |