| Electronic Components Datasheet Search |
|
PIC16LC62B-04/P Datasheet(PDF) 100 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
PIC16LC62B-04/P Datasheet(HTML) 100 Page - Microchip Technology |
|
100 / 120 page ![]() PIC16C62B/72A DS35008B-page 100 Preliminary © 1998 Microchip Technology Inc. FIGURE 13-16: I2C BUS DATA TIMING TABLE 13-12: I2C BUS DATA REQUIREMENTS Param. No. Sym Characteristic Min Max Units Conditions 100* THIGH Clock high time 100 kHz mode 4.0 — µs Device must operate at a min- imum of 1.5 MHz 400 kHz mode 0.6 — µs Device must operate at a min- imum of 10 MHz SSP Module 1.5TCY — 101* TLOW Clock low time 100 kHz mode 4.7 — µs Device must operate at a min- imum of 1.5 MHz 400 kHz mode 1.3 — µs Device must operate at a min- imum of 10 MHz SSP Module 1.5TCY — 102* TR SDA and SCL rise time 100 kHz mode — 1000 ns 400 kHz mode 20 + 0.1Cb 300 ns Cb is specified to be from 10-400 pF 103* TF SDA and SCL fall time 100 kHz mode — 300 ns 400 kHz mode 20 + 0.1Cb 300 ns Cb is specified to be from 10-400 pF 90* TSU:STA START condition setup time 100 kHz mode 4.7 — µs Only relevant for repeated START condition 400 kHz mode 0.6 — µs 91* THD:STA START condition hold time 100 kHz mode 4.0 — µs After this period the first clock pulse is generated 400 kHz mode 0.6 — µs 106* THD:DAT Data input hold time 100 kHz mode 0 — ns 400 kHz mode 0 0.9 µs 107* TSU:DAT Data input setup time 100 kHz mode 250 — ns Note 2 400 kHz mode 100 — ns 92* TSU:STO STOP condition setup time 100 kHz mode 4.7 — µs 400 kHz mode 0.6 — µs 109* TAA Output valid from clock 100 kHz mode — 3500 ns Note 1 400 kHz mode — — ns 110* TBUF Bus free time 100 kHz mode 4.7 — µs Time the bus must be free before a new transmission can start 400 kHz mode 1.3 — µs Cb Bus capacitive loading — 400 pF * These parameters are characterized but not tested. Note 1: As a transmitter, the device must provide this internal minimum delay time to bridge the undefined region (min. 300 ns) of the fall- ing edge of SCL to avoid unintended generation of START or STOP conditions. 2: A fast-mode (400 kHz) I2C-bus device can be used in a standard-mode (100 kHz) I2C-bus system, but the requirement Tsu:DAT ≥ 250 ns must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line TR max.+tsu;DAT = 1000 + 250 = 1250 ns (according to the standard-mode I2C bus specification) before the SCL line is released. Note: Refer to Figure 13-4 for load conditions. 90 91 92 100 101 103 106 107 109 109 110 102 SCL SDA In SDA Out |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |