149 / 355 page ![]() 38B5 Group User’s Manual APPLICATION 2-61 2.3 Serial I/O Fig. 2.3.36 Registers setting relevant to reception side 1 1 1 1 1 1 SIO2CON UART control register (address 001716) UARTCON Serial I/O2 clock: SCLK21 0 SIO2STS Reception side Serial I/O2 status register (address 001E16) Receive buffer full flag Confirm completion of receiving 1-byte data with this flag. “1” : at completing reception “0” : at reading out contents of Receive buffer register Overrun error flag “1” : When data is ready in Receive shift register while Receive buffer register contains the data. Serial I/O2 control register (address 001D16) Synchronous clock: External clock input SRDY2 output enabled Transmit enabled When using SRDY2 output, set this bit to “1”. Receive disabled Clock synchronous serial I/O Serial I/O2 enabled |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|