14 / 84 page ![]() M90E32AS [Datasheet] Atmel-46003B-SE-M90E32AS-Datasheet_02122015 14 3.5.3 ENERGY PULSE OUTPUT CF1 is fixed to be total active energy output (all-phase-sum). Both forward and reverse energy registers can generate the CF pulse (change of forward/ reverse direction can generate an interrupt if enabled). CF2 is reactive energy output (all-phase-sum) by default. It can also be configured to be arithmetic sum apparent energy output (all-phase-sum). CF3 is fixed to be active fundamental energy output (all-phase-sum). CF4 is fixed to be active harmonic energy output (all-phase-sum). Figure-5 CFx Pulse Output Regulation For CFx pulse width regulation, refer to Figure-5. Case1 T>=160ms, Tp=80ms Case 2 10ms<=T<160ms, Tp=T/2 3.5.4 STARTUP AND NO-LOAD POWER There are startup power threshold registers (e.g. PStartTh(35H)). Refer to 5.4 Configuration and Calibration Registers. The power threshold registers are defined for all-phase-sum active, reactive and apparent power. The M90E32AS starts meter- ing when the corresponding all-phase-sum power is greater than the startup threshold. When the power value is lower than the startup threshold, energy is not accumulated and it is assumed as in no-load status. Refer to Figure-6. There are also no-load Current Threshold registers for Active, Reactive and Apparent energy metering participation for each of the 3 phases. If |P|+|Q| is lower than the corresponding power threshold, that particular phase will not be accumu- lated. Refer to the PStartTh register and other threshold registers. There are also no-load status bits (the TPnoload/TQnoload bits (b14~15, Fundamental / Harmonic Energy Register)) defined to reflect the no-load status. The M90E32AS does not output any pulse in no-load status. The power-on state is of no-load status. Figure-6 Active Power Startup/Noload Processing CFx Tp=80ms Tp=0.5T T≥160ms 10ms≤T<160ms Phase Active Energy Metering 0 1 0 Total Active Energy Metering ABS > PStartTh? 0 1 0 Total Active Power 0 1 Phase Active Power from DSP 0 Phase |P| + |Q| > PPhaseTh? 0 1 Phase Active Power from DSP 0 Phase |P| + |Q| > PPhaseTh? 0 1 Phase Active Power from DSP 0 Phase |P| + |Q| > PPhaseTh? C A B Active Power Startup/Noload handling NoLoad Status |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |