| Electronic Components Datasheet Search |
|
ADIS16IMU1/PCBZ Datasheet(PDF) 15 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADIS16IMU1/PCBZ Datasheet(HTML) 15 Page - Analog Devices |
|
15 / 38 page ![]() Data Sheet ADIS16486 Rev. 0 | Page 15 of 38 USER REGISTER DEFINITIONS Page Number (PAGE_ID) The contents in the PAGE_ID register (see Table 12 and Table 13) contain the current page setting and provide a control for selecting another page for SPI access. For example, set DIN = 0x8002 to select Page 2 for SPI-based user access. See Table 10 for the page assignments associated with each user accessible register. Table 12. PAGE_ID Register Definition Page ID Addresses Default Access Flash Backup 0x00 0x00, 0x01 0x0000 R/W No Table 13. PAGE_ID Bit Definition Bits Description (Default = 0x0000) [15:0] Page number, binary numerical format Data and Sample Counter (DATA_CNT) The DATA_CNT register (see Table 14 and Table 15) is a continuous, real-time, sample counter. The counter starts at 0x0000, increments every time that the sensor output data registers update, and wraps around from 0xFFFF to 0x0000. Table 14. DATA_CNT Register Definition Page ID Addresses Default Access Flash Backup 0x00 0x04, 0x05 Not applicable R No Table 15. DATA_CNT Bit Definition Bits Description (No Default) [15:0] Data counter, binary format Internal Power Supply Monitor (SENS_PWR) The SENS_PWR register (see Table 16 and Table 17) is a read only register that provides a measurement of the internal power supply. Table 18 provides some examples of the data format. Table 16. SENS_PWR Register Definition Page ID Addresses Default Access Flash Backup 0x00 0x06, 0x07 Not applicable R No Table 17. SENS_PWR Bit Definition Bits Description (No Default) [15:0] Relative power supply measurement, twos complement (see Equation 1) 16 15 2.5 V _ 22 LSB SENS PWR Supply = ×− (1) Table 18. SENS_PWR Data Format Examples Supply Level (V) Decimal Hex Binary 4.90 +669 0x029D 0000 0010 1001 1101 4.95 +331 0x014B 0000 0001 0100 1011 5 0 0x0000 0000 0000 0000 0000 5.05 −324 0xFEBC 1111 1110 1011 1100 5.10 −643 0xFD7D 1111 1101 0111 1101 Status and Error Flag Indicators (SYS_E_FLAG) The SYS_E_FLAG register (see Table 19 and Table 20) provides various error flags. Reading this register causes its bits to return to 0, except for Bit 7. If an error condition persists, the flag (bit) automatically returns an alarm value of 1. Table 19. SYS_E_FLAG Register Definition Page ID Addresses Default Access Flash Backup 0x00 0x08, 0x09 0x0000 R No Table 20. SYS_E_FLAG Bit Definitions Bits Description (Default = 0x0000) 15 Watch dog timer flag. A 1 indicates that the ADIS16486 automatically resets itself to clear an issue. [14:9] Not used. 8 Internal power supply monitor. A 1 indicates an issue with the power supply for the sensors. Initiate a reset to recover. Replace the ADIS16486 if this error persists. 7 Processing overrun. A 1 indicates the occurrence of a processing overrun. Initiate a reset to recover. Replace the ADIS16486 if this error persists. One potential source of this error is not providing power to the VDDRTC pin. 6 Flash memory update failure. A 1 indicates that the most recent flash memory update (GLOB_CMD, Bit 3, see Table 141) failed. Repeat the test and replace the ADIS16486 if this error persists. 5 Sensor failure. A 1 indicates the failure of at least one of the self test processes: continuous or on demand. Run the ODST (GLOB_CMD, Bit 1, see Table 141) when the unit is in not in motion. Replace the ADIS16486 if the error persists. 4 Overrange. A 1 indicates that the digital magnitude of at least one sensor has reached 99% of its maximum value. Initiate a reset to recover and replace the ADIS16486 if this error persists. 3 SPI communication error. A 1 indicates that the total number of SCLK cycles is not equal to an integer multiple of 16. Repeat the previous communication sequence to recover. Persistence in this error can indicate a weakness in the SPI service from the master processor. 2 SRAM error condition. A 1 indicates a failure in the CRC (period = 20 ms) between the SRAM and flash memory. Initiate a reset to recover. Replace the ADIS16486 if this error persists. 1 Boot memory failure. A 1 indicates that the CRC on the primary flash memory bank did not match the reference CRC value, and that the device automatically rebooted using the backup memory bank in flash. Replace the ADIS16486 if this error persists. 0 Alarm status flag. A 1 indicates that one of the user- programmable alarms is active. See the ALM_STS register for an indication of which alarm is active. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |