77 / 182 page ![]() 12.3 GPO error handling Table 48. GPO error handling Type of error Detection condition Action Clear SPI flag Restart condition GPO Overcurrent On state, LS on GPO output switched-off and SPI GPO OVC fault bit (13) latched in SERVFLT register On read Automatic on SPI read Open load (OPL) On state, LS configuration, LS off, diagnostic enabled Set SPI GPO OL (14) fault bit in SERVFLT register On read N.A. Short to GND (STG) On state, LS configuration, LS off Set SPI GPO STG (12) fault bit in SERVFLT register On read N.A. L9300 GPO error handling DS12258 - Rev 4 page 77/182 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|