47 / 92 page ![]() 5.1.3 Registers The results of the digital conversion are stored in the “Digital Current Sense Registers” Two registers are used for the digital conversion of the output current and case sense temperature respectively: • ADCxSR (address from 28h to 2Dh) - for digital Outputx current (one register x channel) • ADC9SR (address 31h) - Digital case temperature sensor voltage sense register Table 38. Registers Register name Bit 15,14 Bit 13..4 Bit 3 Bit 2 Bit 1 Bit 0 ADCxSR 28h to 2Dh Not Used Digital Value of OUTx current Not Used SOCRx Possibility to control the Outx state (Read only) UPDTSR Updated status bit. It is set when value is updated and cleared when register is read Parity ADC9SR 31h Not Used Digital Value of case temperature sensor voltage Not Used Not Used UPDTSR Updated status bit. It is set when value is updated and cleared when register is read Parity 5.1.4 Synchronous, Asynchronous Modes 5.1.4.1 Normal mode The ADC conversion can work in 4 different sampling modes (start, stop, continuous or filtered) according to the table below. Two bits per channel “SPCR1” and “SPCR0” allocated in the Output Configuration Register “OUTCFGRx”, allow 4 different sampling modes: Table 39. Sampling mode configuration SPCR1 SPCR0 Sampling mode 0 0 STOP Mode 0 1 START Mode 1 0 CONTINUOUS Mode 1 1 FILTERED Mode 5.1.4.2 Synchronous mode Synchronous Mode in PWM condition • Sampling is done according to the PWM rising and falling edge (see Figure 21. Sequence of channels). See Table 39. Sampling mode configuration for more details about the registers configuration. • The sampling priority will be always allocated at higher priority Registers configuration • SPCR10=0h: Synchronous triggered by rising edge on internal PWM. Conversion is executed on the rising edge of the conversion window (see Figure 21. Sequence of channels). • The ADC real sampling is managed to trigger the sampling point with margin versus falling edge. • SPCR10=1h: Synchronous triggered by falling edge of the internal PWM signal. Conversion is executed on the falling edge of the conversion window (see Figure 21. Sequence of channels). Note: The ADC real sampling is managed to trigger the sampling point with margin versus rising edge. VN9D7D20F Diagnostic DS13153 - Rev 8 page 47/92 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |