| Electronic Components Datasheet Search |
|
TAS2020 Datasheet(PDF) 28 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TAS2020 Datasheet(HTML) 28 Page - Texas Instruments |
|
28 / 79 page ![]() If the sample rate is properly configured via the SAMPLE_RATE_CFG bits, no additional configuration is required as long as the SBCLK to FSYNC ratio is valid. The device automatically detects the input PCM FSYNC and BCLK frequency and auto configures itself to playback audio signal. The detected clock rates can be read using the read only registers FS_RATIO_DETECTED and FS_RATE_DETECTED. The device detects improper SBCLK frequencies and SBCLK to FSYNC ratios and volume ramp down the playback path to minimize audible artifacts. Table 6-23. Supported SBCLK Frequencies (MHz) (48kHz based sample rates) Sample Rate (kHz) SBCLK to FSYNC Ratio 16 24 32 48 64 96 128 192 256 384 512 125 250 500 16kHz NA 0.384 0.512 0.768 1.024 1.536 2.048 3.072 4.096 6.144 8.192 2 4 8 24kHz 0.384 0.576 0.768 1.152 1.536 2.304 3.072 4.608 6.144 9.216 12.288 3 6 12 32kHz 0.512 0.768 1.024 1.536 2.048 3.072 4.096 6.144 8.192 12.288 16.384 4 8 16 48kHz 0.768 1.152 1.536 2.304 3.072 4.608 6.144 9.216 12.288 18.432 24.576 6 12 24 96kHz 1.536 2.304 3.072 4.608 6.144 9.216 12.288 18.432 24.576 NA NA 12 24 NA 192kHz 3.027 4.608 6.144 9.216 12.288 18.432 24.576 NA NA NA NA 24 NA NA 6.4.5.1 Auto clock based wakeup and clock errors TAS2020 supports flexible operating mode transition from active to shutdown and vice-verse using ASI clock auto detection feature. When MODE[1:0] is configured as '11' the device toggles between Active and Software shutdown state based on valid ASI clock signals applied on the ASI input pins, for example BCLK and FSYNC. If no ASI clocks are detected in this mode, the device remains in software shutdown, with software shutdown mode IQ on VDD pin, until a valid BCLK and FSYNC clock is detected. Once a valid clock is detected, the device is powered up in active state until the clocks are valid or device is shutdown using software or hardware shutdown commands. The device can detect and raise interrupt flags on detection of incorrect clock configurations based on status of CLK_ERR_PWR_EN. When this bit is set high, the device monitors for activity on the clock pins and flags any error using the latched interrupts status register. The device can also raise interrupts using IRQZ pin based on status of the corresponding interrupt MASK registers. When the error protection bit is enabled, if a clock error is detected, the device automatically shuts-down with proper shutdown sequencing and minimize any clicks and pops due to invalid clocks. When the device is in shutdown state, the clock error detection can be delayed to provide system with time required to settle the input clocks. This power up delay in clock error detection is controlled using an internal pre-power up clock error detection timer configured by CLK_HALT_TIMER. If device does not detect a valid clock at the end of the CLK_HALT_TIMER expiry, the Pre-Power-up Clock error is flagged on INT_LTCH4[2] bit, and corresponding interrupt can be generated on IRQZ pin based on status of INT_MASK4[2] bit. When MODE[1:0] is configured as '11' (Wake-up on ASI mode), CLK_HALT_TIMER of '000' is not recommended and MODE[1:0] stops the device from entering the software shutdown and increases the VDD IQ while the device is shutdown. Once the device is powered up, the external and internally generated clocks are constantly monitored based on status of CLK_ERR_PWR_EN bit. If enabled, any error in external or internal clock is flagged using the clock error status register INT_LTCH2[3] bit, and corresponding interrupt can be generated on IRQZ pin based on status of INT_MASK2[3]. For system flexibility, the device also sets the error status for the type of detected clock error. The device can also be configured to raise an interrupt on IRQZ pin for any specific type of clock error, instead of using the generic clock error interrupt generation. Table 6-26 below explains the different type of clock errors and corresponding status bits and interrupt MASK register bits. One or more register bits in the table below can be set based on the type of clock error detected. If the device shuts down due to any type of clock error, the device can attempt to re-power itself automatically when MODE[1:0] is set to '11'. TAS2020 SLASFD4A – AUGUST 2024 – REVISED JULY 2026 www.ti.com 28 Submit Document Feedback Copyright © 2026 Texas Instruments Incorporated Product Folder Links: TAS2020 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |