Back Button LM5064PMH/NOPB Datasheet HTML 19Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 20Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 21Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 22Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 23Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 24Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 25Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 26Page - Texas Instruments LM5064PMH/NOPB Datasheet HTML 27Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 23 / 64 page
background image
LM5064
www.ti.com
SNVS718E – JUNE 2011 – REVISED FEBRUARY 2013
TIMER CAPACITOR, CT
The TIMER pin capacitor (CT) sets the timing for the insertion time delay, fault timeout period, and the restart
timing of the LM5064.
A) Insertion Delay -Upon applying the system voltage (VSYS) to the circuit, the external MOSFET (Q1) is held off
during the insertion time (t1 in Figure 2) to allow ringing and transients at VSYS to settle. Since each backplane’s
response to a circuit card plug-in is unique, the worst case settling time must be determined for each application.
The insertion time starts when VSYS reaches the POR threshold, at which time the internal 4.8 µA current source
charges CT from 0V to 3.9V. The required capacitor value is calculated from:
(7)
For example, if the desired insertion delay is 125 ms, CT calculates to 0.15 µF. At the end of the insertion delay,
CT is quickly discharged by a 1.5 mA current sink.
B) Fault Timeout Period -During in-rush current limiting or upon detection of a fault condition where the current
limit and/or power limit circuits regulate the current through Q1, the fault timer current source (74 µA) is switched
on to charge CT. The Fault Timeout Period is the time required for the TIMER pin voltage to reach 3.9V, at which
time Q1 is switched off. The required capacitor value for the desired Fault Timeout Period tFAULT is calculated
from:
(8)
For example, if the desired Fault Timeout Period is 8 ms, CT calculates to 0.15 µF. CT is discharged by the 2.4
µA current sink at the end of the Fault Timeout Period. After the Fault Timeout Period, if RETRY = VDD, the
LM5064 latches the GATE pin low until a power up sequence is initiated by external circuitry. When the Fault
Timeout Period of the LM5064 expires, a restart sequence starts as described below (Restart Timing). During
consecutive cycles of the restart sequence, the fault timeout period is shorter than the initial fault time out period
described above by approximately 8% since the voltage at the TIMER pin starts ramping up from 0.3V rather
than VEE.
Since the LM5064 normally operates in power limit and/or current limit during a power up sequence, the Fault
Timeout Period MUST be longer than the time required for the output voltage to reach its final value. See the
TURN-ON TIME section.
C) Restart Timing For the LM5064, after the Fault Timeout Period described above, CT is discharged by the 2.4
µA current sink to 1.2V. The TIMER pin then cycles through seven additional charge/discharge cycles between
1.2V and 3.9V as shown in Figure 4. The restart time ends when the TIMER pin voltage reaches 0.3V during the
final high-to-low ramp. The restart time, after the Fault Timeout Period, is equal to:
(9)
= CT x 9.6 x 10
6
(10)
For example, if CT = 0.15 µF, tRESTART = 1.4 seconds. At the end of the restart time, Q1 is switched on. If the fault
is still present, the fault timeout and restart sequence repeats. The on-time duty cycle of Q1 is approximately
0.5% in this mode.
UVLO, OVLO
By programming the UVLO and OVLO thresholds the LM5064 enables the series pass device (Q1) when the
input supply voltage (VSYS) is within the desired operational range. If VCC is below the UVLO threshold, or above
the OVLO threshold, Q1 is switched off, denying power to the load. Hysteresis is provided for each threshold.
Copyright © 2011–2013, Texas Instruments Incorporated
Submit Documentation Feedback
23
Product Folder Links: LM5064



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com