100 / 159 page ![]() 100 AT89C51ID2 4289A–8051–09/03 drive the network. The Master may select each Slave device by software through port pins (Figure 37). To prevent bus conflicts on the MISO line, only one slave should be selected at a time by the Master for a transmission. In a Master configuration, the SS line can be used in conjunction with the MODF flag in the SPI Status register (SPSTA) to prevent multiple masters from driving MOSI and SCK (See Error conditions). A high level on the SS pin puts the MISO line of a Slave SPI in a high-impedance state. The SS pin could be used as a general purpose if the following conditions are met: • The device is configured as a Master and the SSDIS control bit in SPCON is set. This kind of configuration can be found when only one Master is driving the network and there is no way that the SS pin could be pulled low. Therefore, the MODF flag in the SPSTA will never be set(1). • The Device is configured as a Slave with CPHA and SSDIS control bits set(2) This kind of configuration can happen when the system comprises one Master and one Slave only. Therefore, the device should always be selected and there is no reason that the Master uses the SS pin to select the communicating Slave device. Note: 1. Clearing SSDIS control bit does not clear MODF. 2. Special care should be taken not to set SSDIS control bit when CPHA =’0’ because in this mode, the SS is used to start the transmission. Baud rate In Master mode, the baud rate can be selected from a baud rate generator which is con- trolled by three bits in the SPCON register: SPR2, SPR1 and SPR0.The Master clock is chosen from one of seven clock rates resulting from the division of the internal clock by 2, 4, 8, 16, 32, 64 or 128. Table 76 gives the different clock rates selected by SPR2:SPR1:SPR0: Table 76. SPI Master Baud Rate Selection SPR2 SPR1 SPR0 Clock Rate Baud rate divisor (BD) 0 0 0 Don’t Use No BRG 001 F CLK PERIPH /4 4 010 F CLK PERIPH / 8 8 011 F CLK PERIPH /16 16 100 F CLK PERIPH /32 32 101 F CLK PERIPH /64 64 110 F CLK PERIPH /128 128 1 1 1 Don’t Use No BRG |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |