| Electronic Components Datasheet Search |
|
71M6545HT-IGT/F Datasheet(PDF) 18 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
71M6545HT-IGT/F Datasheet(HTML) 18 Page - Maxim Integrated Products |
|
18 / 66 page ![]() Maxim Integrated │ 18 71M6545T/71M6545HT Energy Meter ICs www.maximintegrated.com Hardware Description The 71M6545T/HT single-chip energy meter ICs integrate all primary functional blocks required to implement a solid-state residential electricity meter. Included on the chip are the following: • An analog front-end (AFE) featuring a 22-bit second- order sigma-delta ADC • An independent 32-bit digital computation engine (CE) to implement DSP functions • An 8051-compatible microprocessor (MPU) which executes one instruction per clock cycle (80515) • A precision voltage reference (VREF) • Atemperature sensor for digital temperature compensation: • Metrology digital temperature compensation (MPU) • Automatic RTC digital temperature compensation operational in all power states • RAM and flash memory • A real-time clock (RTC) • A variety of I/O pins • A power-failure interrupt • A zero-crossing interrupt • Selectable current sensor interfaces for locally-connect- ed sensors as well as isolated sensors (i.e., using the 71M6x03 companion IC with a shunt resistor sensor) • Resistive shunt and current transformers are supported Resistive shunts and current transformer (CT) current sensors are supported. Resistive shunt current sensors may be connected directly to the 71M654xT device or isolated using a companion 71M6x03 isolator IC in order to implement a variety of metering configurations. An inexpensive, small pulse transformer is used to isolate the 71M6x03 isolated sensor from the 71M654xT. The 71M654xT performs digital communications bidirectionally with the 71M6x03 and also provides power to the 71M6x03 through the isolating pulse transformer. Isolated (remote) shunt current sensors are connected to the differential input of the 71M6x03. Included on the 71M6x03 companion isolator chip are: • Digital isolation communications interface • An analog front-end (AFE) • A precision voltage reference (VREF) • A temperature sensor (for digital temperature compen- sation) • A fully differential shunt resistor sensor input • A preamplifier to optimize shunt current sensor perfor- mance • Isolated power circuitry obtains dc power from pulses sent by the 71M654xT In a typical application, the 32-bit compute engine (CE) of the 71M654xT sequentially processes the samples from the voltage inputs on analog input pins and from the external 71M6x03 isolated sensors and performs calculations to measure active energy (Wh) and reactive energy (VARh), as well as A2h, and V2h for four-quadrant metering. These measurements are then accessed by the MPU, processed further and output using the peripheral devices available to the MPU. In addition to advanced measurement functions, the clock function allows the 71M6545T/HT to record time-of-use (TOU) metering information for multi-rate applications and to time-stamp tamper or other events. In addition to the temperature-trimmed ultra-precision voltage reference, the on-chip digital temperature compensation mechanism includes a temperature sensor and associated controls for correction of unwanted temperature effects on measurement and RTC accuracy, e.g., to meet the requirements of ANSI and IEC standards. Temperature-dependent external components such as crystal oscillator, resistive shunts, current transformers (CTs) and their corresponding signal conditioning circuits can be characterized and their correction factors can be programmed to produce electricity meters with exceptional accuracy over the industrial temperature range. See the Block Diagram. Analog Front-End (AFE) The AFE functions as a data acquisition system, controlled by the MPU. When used with locally connected sensors, as shown in Figure 2, the analog input signals (IADC0- IADC7, VADC8-VADC10) are multiplexed to the ADC input and sampled by the ADC. The ADC output is decimated by the FIR filter and stored in CE RAM where it can be accessed and processed by the CE. When remote isolated sensors are connected to the 71M6545T/HT using 71M6x03 remote sensor interfaces, the input multiplexer is bypassed. Instead, the extracted modulator bit stream is passed directly to a dedicated decimation filter. The output of the decimation filter is then directly stored in the appropriate CE RAM location without making use of a multiplexer cycle. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |