Back Button 71M6545HT-IGT/F Datasheet HTML 20Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 21Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 22Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 23Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 24Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 25Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 26Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 27Page - Maxim Integrated Products 71M6545HT-IGT/F Datasheet HTML 28Page - Maxim Integrated Products Next Button
Zoom Inzoom in Zoom Outzoom out
 24 / 66 page
background image
Maxim Integrated │ 24
71M6545T/71M6545HT
Energy Meter ICs
www.maximintegrated.com
Isolated Sensor Interface
Nonisolating sensors, such as shunt resistors, can be
connected to the inputs of the 71M654xT through a
combination of a pulse transformer and a 71M6x03
isolated sensor interface. The 71M6x03 receives power
directly from the 71M654xT through a pulse transformer
and does not require a dedicated power supply circuit.
The 71M6x03 establishes 2-way communication with
the 71M654xT, supplying current samples and auxiliary
information such as sensor temperature through a serial
data stream.
Up to three 71M6x03 isolated sensors can be supported
by the 71M6545T/HT. When a remote sensor interface is
enabled, the two analog current inputs become reconfig-
ured as a digital remote sensor interface. Each 71M6x03
isolated sensor consists of the following building blocks:
• Power supply for power pulses received from the
71M654xT
• Digital communications interface
• Shunt signal preamplifier
• Delta-sigma ADC converter with precision bandgap
reference (chopping amplifier)
• Temperature sensor
• Fuse system containing part-specific information
During an ordinary multiplexer cycle, the 71M654xT inter-
nally determines which other channels are enabled. At
the same time, it decimates the modulator output from the
71M6x03 isolated sensors. Each result is written to CE
RAM during one of its CE access time slots.
The ADC of the 71M6x03 derives its timing from the power
pulses generated by the 71M654xT and as a result, oper-
ates its ADC slaved to the frequency of the power pulses.
The generation of power pulses, as well as the commu-
nication protocol between the 71M654xT and 71M6x03
isolated sensor is automatic and transparent to the user.
The 71M654xT can read data and status from, and
can write control information to the 71M6x03 isolated
sensor. With hardware and trim-related information on
each connected 71M6x03 isolated sensor available to
the 71M6545T/HT, the MPU can implement temperature
compensation of the energy measurement based on the
individual temperature characteristics of the 71M6x03
isolated sensor.
Digital Computation Engine (CE)
The CE, a dedicated 32-bit signal processor, performs the
precision computations necessary to accurately measure
energy. The CE calculations and processes include:
• Multiplication of each current sample with its associ-
ated voltage sample to obtain the energy per sample
(when multiplied with the constant sample time).
• Frequency-insensitive delay cancellation on all four
channels (to compensate for the delay between sam-
ples caused by the multiplexing scheme).
• 90° phase shifter (for VAR calculations).
• Pulse generation.
• Monitoring of the input signal frequency (for frequency
and phase information).
• Monitoring of the input signal amplitude (for sag detec-
tion).
• Scaling of the processed samples based on calibration
coefficients.
• Scaling of samples based on temperature compensa-
tion information.
Meter Equations
The 71M6545T/HT provides hardware assistance to the
CE in order to support various meter equations. The
compute engine firmware for industrial configurations
can implement the equations listed in Table 2. EQU[2:0]
specifies the equation to be used based on the meter con-
figuration and on the number of phases used for metering.
Real-Time Monitor
The CE contains a real-time monitor (RTM), which can be
programmed to monitor four selectable XRAM locations at
full sample rate. The four monitored locations are serially
output to the TMUXOUT pin via the digital output multi-
plexer at the beginning of each CE code pass. The RTM
can be enabled and disabled with control bit RTM_E. The
RTM output is clocked by CKTEST. Each RTM word is
clocked out in 35 CKCE cycles (1 CKCE cycle is equiva-
lent to 203ns) and contains a leading flag bit.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com