Back Button ADIS16IMU5/PCBZ Datasheet HTML 33Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 34Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 35Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 36Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 37Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 38Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 39Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 40Page - Analog Devices ADIS16IMU5/PCBZ Datasheet HTML 41Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 37 / 46 page
background image
Data Sheet
ADIS16575/ADIS16576/ADIS16577
USER REGISTER DEFINITIONS
analog.com
Rev. 0 | 37 of 46
►
FIFO Output Mode. Fresh sample data is enqueued into an
internal 512 sample FIFO. The data ready signal toggles during
enqueue, allowing sampling rate monitoring. The host system
can asynchronously pop the oldest sample data to the output
registers by reading the DIAG_STAT register.
The FIFO contains six channels of 32-bit inertial data (direct or
delta outputs as per the MSC_CTRL register, OUT_SEL bit, Bit
8), TEMP, DATA_CNTR, and TIME_STAMP. Status flags update
continuously in both modes.
FIFO mode facilitates integration with nonreal-time systems like
embedded Linux, preventing data loss. This mode offers flexibility
in data reading timing and can buffer approximately 256 ms of
samples at 4 kHz ODR. The buffering window can be extended
using the decimation filter.
The watermark interrupt allows FIFO-level monitoring without read-
ing FIFO_CNT. When enabled, this interrupt triggers based on the
samples enqueued vs. the set threshold. This interrupt supports
batch reading of multiple samples. When disabled, the WM pin is
high-Z to prevent potential damage.
FILTER CONTROL REGISTER (FILT_CTRL)
Table 115. FILT_CTRL Register Definition
Addresses
Default
Access
Flash Backup
0x5C, 0x5D
0x0000
R/W
Yes
Table 116. FILT_CTRL Bit Definitions
Bits
Description
[15:3]
Not used
[2:0]
Filter Size Variable B; number of taps in each stage; N = 2B
The FILT_CTRL register (see Table 115 and Table 116) provides
user controls for the Bartlett window FIR filter (see Figure 44),
which contains two cascaded averaging filters.
For example, use the following sequence to set Register
FILT_CTRL, Bits[2:0], = 100, which sets each stage to have 16
taps: 0xCC04 and 0xCD00.
For example, if the user wants each filter stage to have 16 taps, the
number of taps must be determined by using the N = 2B formula,
where B is the value in Bits[2:0] of the FILT_CTRL register. To solve
for B, calculate B = log2(16) = 4. In binary, this value represents
100.
To set this value in the register, follow this sequence:
1. Write 0xCC04 to the FILT_CTRL register. The 04 value sets
Bits[2:0] to 100, corresponding to B = 4. As a result, each stage
of the filter has 16 taps.
2. Write 0xCD00 to the FILT_CTRL register. This value completes
the sequence and confirms the previous setting.
After completing these steps, each stage of the filter has 16 taps,
which affects the characteristics of the filter, including its frequency
response, delay, and noise reduction capability.
Figure 70 provides the frequency response for several settings in
the FILT_CTRL register.
Figure 70. Bartlett Window, FIR Filter Frequency Response (Phase Delay = N
Samples)
RANGE IDENTIFIER (RNG_MDL)
Table 117. RNG_MDL Register Definition
Addresses
Default
Access
Flash Backup
0x5E, 0x5F
Not applicable
R
No
Table 118. RNG_MDL Bit Definitions
Bits
Description
[15:3]
Not used
[3:2]
Gyroscope measurement range
01 = ±450°/sec (ADIS16575-2, ADIS16576-2, and ADIS16577-2)
10 = reserved
00 = reserved
11 = ±2000°/sec (ADIS16576-3, and ADIS16577-3)
[1:0]
Reserved, binary value = 11
MISCELLANEOUS CONTROL REGISTER
(MSC_CTRL)
Table 119. MSC_CTRL Register Definition
Addresses
Default
Access
Flash Backup
0x60, 0x61
0x00C1
R/W
Yes
Table 120. MSC_CTRL Bit Definitions
Bits
Name
Description
[15:13] RESERVED
Not used
12
SENS_BW
Internal Sensor Bandwidth Selection. This bit allows the
selection between two different bandwidths for the IMUs
internal sensors.
0 = wide bandwidth: 639 Hz (gyroscope) and 750 Hz
(accelerometer),
1= medium bandwidth: ~370 Hz on accelerometers and
gyroscopes.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com