| Electronic Components Datasheet Search |
|
ADIS16IMU5/PCBZ Datasheet(PDF) 39 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADIS16IMU5/PCBZ Datasheet(HTML) 39 Page - Analog Devices |
|
39 / 46 page ![]() Data Sheet ADIS16575/ADIS16576/ADIS16577 USER REGISTER DEFINITIONS analog.com Rev. 0 | 39 of 46 Bits[3:2] is 00 (binary), which places the ADIS16575/ADIS16576/ ADIS16577 in internal clock mode. In this mode, an internal clock controls inertial sensor data acquisition and processing at a nominal rate of 2000 Hz (4 kHz if SYNC_4KHZ is enabled). All sensors are sampled at the IMU sample rate, ensuring synchronized data collection across the system. Scaled Sync Mode When Register MSC_CTRL, Bits[3:2] = 10, the ADIS16575/ ADIS16576/ADIS16577 operate in scaled sync mode, supporting a frequency range of 0.8 Hz to 400 Hz for the clock signal on the SYNC pin. This mode is advantageous for synchronizing data processing with signals from other systems, such as a Global Navigation Satellite Systems (GNSS) PSS signal. In scaled sync mode, the sample clock frequency is determined by the product of the external clock scale factor (KECSF), set in the UP_SCALE register (see Table 121 and Table 122), and the frequency of the clock signal on the SYNC pin. For example, to set up a sample rate of 2000 SPS using a 1 Hz input signal, configure the UP_SCALE register with a value of 0x07D0, which corresponds to a KECSF value of 2000 in decimal. This configuration results in a sample rate of 2000 SPS for both the inertial sensors and the signal processing. To achieve this setup, send the sequence 0xE2D0 followed by 0xE307 to the DIN pin. Table 121. UP_SCALE Register Definition Addresses Default Access Flash Backup 0x62, 0x63 0x07D0 R/W Yes Table 122. UP_SCALE Bit Definitions Bits Description [15:0] KECSF; binary format Output Sync Mode When Register MSC_CTRL, Bits[3:2] = 11, the ADIS16575/ ADIS16576/ADIS16577 operate in output sync mode, which is the same as internal clock mode with one exception: the SYNC pin pulses when the internal processor collects data from the inertial sensors. Figure 72 provides an example of this signal. Figure 72. Sync Output Signal, Register MSC_CTRL, Bits[3:2] = 11 Data Update Rate in External Sync Modes When using the input sync option in scaled sync mode (Register MSC_CTRL, Bits[3:2] = 10, see Table 120), the ODR is equal to (fSYNC × KECSF)/(DEC_RATE + 1) where: fSYNC is the clock signal frequency on the SYNC pin. KESCF is the value from the UP_SCALE register (see Table 122). In direct sync mode, the UP_SCALE register is not used, and the ODR directly follows the frequency of the external sync signal on the SYNC pin without any scaling. DECIMATION FILTER (DEC_RATE) Table 123. DEC_RATE Register Definition Addresses Default Access Flash Backup 0x64, 0x65 0x0000 R/W Yes Table 124. DEC_RATE Bit Definitions Bits Description [15:11] Don’t care [10:0] Decimation rate, binary format, maximum = 1999 The DEC_RATE register (see Table 123 and Table 124) gives users control over the averaging decimating filter. This filter averages and decimates the data from the gyroscope and accelerometer, and it also extends the tracking time between each update for the delta angle and delta velocity. When operating the ADIS16575/ ADIS16576/ADIS16577 in the default internal clock mode (refer to the Bits[3:2] in Table 120), users can calculate the nominal ODR using the following formula: fS/(DEC_RATE + 1) where fS is the unit user-selected (2000 or 4000) sample rate. For example, to lower the output sample rate to 100 SPS (2000 ÷ 20), set the DEC_RATE to 0x0013. To do this setting, send the following sequence to the DIN pin: first 0xE413, then 0xE500. CONTINUOUS BIAS ESTIMATION (NULL_CNFG) Table 125. NULL_CNFG Register Definition Addresses Default Access Flash Backup 0x66, 0x67 0x070A R/W Yes Table 126. NULL_CNFG Bit Definitions Bits Description [15:14] Not used 13 Z-axis accelerometer bias correction enable (1 = enabled) 12 Y-axis accelerometer bias correction enable (1 = enabled) 11 X-axis accelerometer bias correction enable (1 = enabled) 10 Z-axis gyroscope bias correction enable (1 = enabled) 9 Y-axis gyroscope bias correction enable (1 = enabled) 8 X-axis gyroscope bias correction enable (1 = enabled) [7:4] Not used [3:0] Time base control (TBC), range: 0 to 12 (default = 10); tB = 2TBC/fS, fS = the internal sample clock frequency (either 2000 Hz or 4000 Hz |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |