ATmega64A Datasheet(PDF) 42 Page - ATMEL Corporation |
|
|
|||||||||||||||||||||||||||||
ATmega64A Datasheet(HTML) 42 Page - ATMEL Corporation |
|
42 / 392 page ![]() 42 8160C–AVR–07/09 ATmega64A 8.7 Calibrated Internal RC Oscillator The calibrated internal RC Oscillator provides a fixed 1.0, 2.0, 4.0, or 8.0 MHz clock. All frequen- cies are nominal values at 5V and 25 ⋅C. This clock may be selected as the system clock by programming the CKSEL Fuses as shown in Table 8-7. If selected, it will operate with no exter- nal components. The CKOPT Fuse should always be unprogrammed when using this clock option. During reset, hardware loads the calibration byte into the OSCCAL Register and thereby automatically calibrates the RC Oscillator. At 5V, 25 ⋅C and 1.0 MHz Oscillator frequency selected, this calibration gives a frequency within ± 3% of the nominal frequency. Using run-time calibration methods as described in application notes available at www.atmel.com/avr it is possi- ble to achieve ± 1% accuracy at any given V CC and Temperature. When this Oscillator is used as the chip clock, the Watchdog Oscillator will still be used for the Watchdog Timer and for the Reset Time-out. For more information on the preprogrammed calibration value, see the section “Calibration Byte” on page 298. Note: 1. The device is shipped with this option selected. When this Oscillator is selected, start-up times are determined by the SUT Fuses as shown in Table 8-8. XTAL1 and XTAL2 should be left unconnected (NC). Note: 1. The device is shipped with this option selected. 8.8 External Clock To drive the device from an external clock source, XTAL1 should be driven as shown in Figure 8-5. To run the device on an external clock, the CKSEL Fuses must be programmed to “0000”. By programming the CKOPT Fuse, the user can enable an internal 36 pF capacitor between XTAL1 and GND. Table 8-7. Internal Calibrated RC Oscillator Operating Modes CKSEL3:0 Nominal Frequency (MHz) 0001(1) 1.0 0010 2.0 0011 4.0 0100 8.0 Table 8-8. Start-up Times for the Internal Calibrated RC Oscillator Clock Selection SUT1:0 Start-up Time from Power- down and Power-save Additional Delay from Reset (V CC = 5.0V) Recommended Usage 00 6 CK – BOD enabled 01 6 CK 4.1 ms Fast rising power 10(1) 6 CK 65 ms Slowly rising power 11 Reserved |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |