| Electronic Components Datasheet Search |
|
PDP83TG720SWCSTQ1 Datasheet(PDF) 31 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
PDP83TG720SWCSTQ1 Datasheet(HTML) 31 Page - Texas Instruments |
|
31 / 199 page ![]() Table 7-2. Datapath BIST Programming (continued) Loopback Mode To enable loopback mode To enable data generator and checker : MAC packets To check in- coming MAC packets status To enable data generator and checker : PRBS stream To check in- coming PRBS status : PRBS stream Other care- abouts 7 SGMII Reverse loopback • write : reg[0x042C] = 0x0010 • write : reg[0x0619 ]=0x1115 • write : reg[0x0624 ]=0x55BF • read : reg[0x063C] for [15:0] of total received packets count. • read : reg[0x063D] for [31:16] of total received packets count. • read : reg[0x063E] for Packets received with CRC errors • write : reg[0x0619 ]=0x0557 • write : reg[0x0624 ]=0x55BF Step 1 : write : reg[0x0620][1] = 1'b1 Step 2 : • read : reg[0x0620] [7:0] for Number of error bytes received. • read : reg[0x0620] [8] (1 indicates PRBS data is coming in and checker is locked) • Generated data will be going to Cu cable side, to disable this transmissio n : write reg[0x041F] = 0x1000 Note : Different MAC packet parameters can be further configured with register[0x061B] and register[0x0624] 7.3.1.4 Temperature and Voltage Sensing Temperature sensor of PHY can be used to give the indication of the temperature of the system and reading can be taken on the fly by reading the temperature sensor output register. Voltage sensor senses the voltage of all the supply pins : vdda, vddio and vdd1p0. Each pins active voltage can be sensed by reading the corresponding voltage sensor output register. All sensors are always active and monitor state machine polls the value of each sensor periodically. Monitor state machine can be further programmed to give higher priority/sampling time to one sensor over another by using MONITOR_CTRL_3 register. Following software sequence can be used to read out any sensor's output : • Step1 : Program register[0x0467] = 0x6004 ; Initial configuration of monitors • Step 2 : Program register [0x046A] = 0x00A6 and then register [0x046A]=0x00A3; Refresh the monitors • Step 3 : Program register[0x0468] to select the corresponding sensor to be polled and read register [0x047B] [14:7] for selected sensor's output code. • Step 4 : Feed the values of read sensor's output code (in decimal) in following equations to get the sensor's output value in decimals. Refer to Sensor Select Table for required value of constants to be used in equations : – vdda_value = 3.3 + (vdda_output_code - vdda_output_mean_code)*slope_vdda_sensor – vdd1p0_value = 1.0 + (vdd1p0_output_code - vdd1p0_ouput_mean_code)*slope_vdd1p0_sensor – vddio_calculated = 3.3 + (vddio_ouput_code - vddio_output_mean_code)*slope_vddio_sensor – temperature_calculated = 25 + (temperature_output_code - temperature_output_mean_code)*slope_temperature_sensor Table 7-3. Sensor Select Table Register[0x0468] Sensor Selected To Read-out 0x1920 VDDA Voltage Sensor 0x2920 VDD1P0 Voltage Sensor 0x3920 VDDIO Voltage Sensor www.ti.com DP83TG720S-Q1 SNLS604 – SEPTEMBER 2020 Copyright © 2020 Texas Instruments Incorporated Submit Document Feedback 31 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |