102 / 236 page ![]() LR2021 Final Datasheet Rev. 1.1 DS.LR2021 10/14/25 102 of 236 Semtech Proprietary & Confidential LR2021 www.semtech.com 6.3.12 SetLoraCAD The SetLoraCAD command puts the chip into Channel Activity Detection (CAD) mode, where it actively searches for LoRa activity in the specified channel. Channel Activity Detection (CAD) is a LoRa-specific mode of operation that enables the device to search for the presence of LoRa preamble symbols or any LoRa signal, depending on the configuration set through the SetLoraCadParams command. The length of the CAD search period is determined by the parameters specified in the SetLoraCadParams command. At the end of the search period, the device generates the CadDone IRQ. If a valid signal is detected, it also triggers the CadDetected IRQ. CAD supports multi-SF detections, allowing the device to perform CAD for multiple spreading factors in parallel. The same rules that apply to multi-SF detections also apply to multi-CAD. To configure multi-CAD, the following steps should be followed: Set the packet type to LoRa using SetPacketType . Configure the LoRa modulation parameters using SetLoraModulationParams. Set the LoRa packet parameters using SetLoraPacketParams. Configure the CAD parameters using SetLoraCadParams. Set the side detectors configuration using SetLoraSideDetConfig. Enter Rx mode with SetLoraCAD. Calling SetLoraModulationParams disables all side detectors, and they need to be reconfigured by the developer. Depending on the configured CadExitMode (using SetLoraCadParams command), the device either goes back to the configured fallback mode, stays in Rx, or goes to Tx after CAD operation is completed. In fast-multi-CAD mode (when pnr_delta is not equal to 0), the main SF (the largest SF) determines the not-detect condition. The CadDetected IRQ can occur multiple times during the n-symbols window, even for the same SF. The list of SFs that triggered the IRQ can be retrieved using the GetLoraPacketStatus command. It is worth noting that multi-SF Rx detection (not multi-SF CAD) is generally preferred when the exit mode is Rx, as CAD-RX has worse detection performance compared to normal Rx. The choice between multi-SF and multi-CAD depends on the specific application requirements and trade-offs between detection performance and power consumption. 3 51 51 52 54 56 60 60 65 4 51 51 51 54 56 60 60 64 Table 6-20: SetLoRaCAD Command Byte 0 1 Data from host 0x02 0x28 Data to host Stat(15:8) Stat(7:0) Table 6-19: Lora CAD Recommended det_peak values Number of symbols SF5 SF6 SF7 SF8 SF9 SF10 SF11 SF12 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |